Paper
27 July 1979 Designing Principles And Dynamic Tests Of Picosecond Image-Converter Cameras
V. I. Lozovoi, v. E. Postovalov, A. M. Prokhorov, Yu. N. Serduchenko, M. Ya. Schelev
Author Affiliations +
Proceedings Volume 0189, 13th Intl Congress on High Speed Photography and Photonics; (1979) https://doi.org/10.1117/12.957609
Event: 13th International Congress on High Speed Photography and Photonics, 1978, Tokyo, Japan
Abstract
Basic requirements imposed on image-converter tubes (ICT) and pulsed control circuitry intended for construc-tion of reliable image-converter camera (ICC) are briefly discussed. One of the prototype of the EOK-2 portable picosecond camera developed for laser and laser plasma diagnostics is exhibited. In order to proceed many kinds of dynamic tests three different types of Nd-glass and YAG lasers are employed. The camera temporal resolution and dynamic range are established by recording of mode-beats and single pulse laser radiation with prcisely known values. At a maximum streak spead of 2.2 109cm/s the camera provides temporal resolution of lOps at dynamic range of about 30.
© (1979) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
V. I. Lozovoi, v. E. Postovalov, A. M. Prokhorov, Yu. N. Serduchenko, and M. Ya. Schelev "Designing Principles And Dynamic Tests Of Picosecond Image-Converter Cameras", Proc. SPIE 0189, 13th Intl Congress on High Speed Photography and Photonics, (27 July 1979); https://doi.org/10.1117/12.957609
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Cameras

Picosecond phenomena

Temporal resolution

Laser development

Mirrors

Neodymium glass lasers

Oscillators

RELATED CONTENT

Subnanosecond Nd YAG laser with multipass cell for SBS...
Proceedings of SPIE (February 17 2017)
Recent progress in x-ray laser research in JAERI
Proceedings of SPIE (September 13 2005)
High-power CPA Nd:glass laser development at ILE
Proceedings of SPIE (December 08 1997)
328 MHz synchroscan streak camera
Proceedings of SPIE (April 01 1991)

Back to Top