Paper
19 October 2016 Model-based x-ray energy spectrum estimation algorithm from CT scanning data with spectrum filter
Author Affiliations +
Proceedings Volume 10155, Optical Measurement Technology and Instrumentation; 101553S (2016) https://doi.org/10.1117/12.2247466
Event: International Symposium on Optoelectronic Technology and Application 2016, 2016, Beijing, China
Abstract
With the development of technology, the traditional X-ray CT can’t meet the modern medical and industry needs for component distinguish and identification. This is due to the inconsistency of X-ray imaging system and reconstruction algorithm. In the current CT systems, X-ray spectrum produced by X-ray source is continuous in energy range determined by tube voltage and energy filter, and the attenuation coefficient of object is varied with the X-ray energy. So the distribution of X-ray energy spectrum plays an important role for beam-hardening correction, dual energy CT image reconstruction or dose calculation. However, due to high ill-condition and ill-posed feature of system equations of transmission measurement data, statistical fluctuations of X ray quantum and noise pollution, it is very hard to get stable and accurate spectrum estimation using existing methods. In this paper, a model-based X-ray energy spectrum estimation method from CT scanning data with energy spectrum filter is proposed. First, transmission measurement data were accurately acquired by CT scan and measurement using phantoms with different energy spectrum filter. Second, a physical meaningful X-ray tube spectrum model was established with weighted gaussian functions and priori information such as continuity of bremsstrahlung and specificity of characteristic emission and estimation information of average attenuation coefficient. The parameter in model was optimized to get the best estimation result for filtered spectrum. Finally, the original energy spectrum was reconstructed from filtered spectrum estimation with filter priori information. Experimental results demonstrate that the stability and accuracy of X ray energy spectrum estimation using the proposed method are improved significantly.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Lei Li, Lin-Yuan Wang, and Bin Yan "Model-based x-ray energy spectrum estimation algorithm from CT scanning data with spectrum filter", Proc. SPIE 10155, Optical Measurement Technology and Instrumentation, 101553S (19 October 2016); https://doi.org/10.1117/12.2247466
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Data modeling

Computed tomography

Model-based design

Optical filters

X-ray computed tomography

RELATED CONTENT

Optical processing for model-based vision
Proceedings of SPIE (February 01 1992)
Noise simulation in x-ray CT
Proceedings of SPIE (April 20 2005)
Intrathoracic airway measurement: ex-vivo validation
Proceedings of SPIE (May 09 1997)
Limited view angle iterative CT reconstruction
Proceedings of SPIE (February 10 2012)

Back to Top