Paper
22 August 2017 Validation of a semi-automatic protocol for the assessment of the tear meniscus central area based on open-source software
Hugo Pena-Verdeal, Carlos Garcia-Resua, Eva Yebra-Pimentel, Maria J. Giraldez
Author Affiliations +
Proceedings Volume 10453, Third International Conference on Applications of Optics and Photonics; 104530O (2017) https://doi.org/10.1117/12.2271783
Event: Third International Conference on Applications of Optics and Photonics, 2017, Faro, Portugal
Abstract
Purpose: Different lower tear meniscus parameters can be clinical assessed on dry eye diagnosis. The aim of this study was to propose and analyse the variability of a semi-automatic method for measuring lower tear meniscus central area (TMCA) by using open source software. Material and methods: On a group of 105 subjects, one video of the lower tear meniscus after fluorescein instillation was generated by a digital camera attached to a slit-lamp. A short light beam (3x5 mm) with moderate illumination in the central portion of the meniscus (6 o’clock) was used. Images were extracted from each video by a masked observer. By using an open source software based on Java (NIH ImageJ), a further observer measured in a masked and randomized order the TMCA in the short light beam illuminated area by two methods: (1) manual method, where TMCA images was “manually” measured; (2) semi-automatic method, where TMCA images were transformed in an 8-bit-binary image, then holes inside this shape were filled and on the isolated shape, the area size was obtained. Finally, both measurements, manual and semi-automatic, were compared. Results: Paired t-test showed no statistical difference between both techniques results (p = 0.102). Pearson correlation between techniques show a significant positive near to perfect correlation (r = 0.99; p < 0.001). Conclusions: This study showed a useful tool to objectively measure the frontal central area of the meniscus in photography by free open source software.
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Hugo Pena-Verdeal, Carlos Garcia-Resua, Eva Yebra-Pimentel, and Maria J. Giraldez "Validation of a semi-automatic protocol for the assessment of the tear meniscus central area based on open-source software", Proc. SPIE 10453, Third International Conference on Applications of Optics and Photonics, 104530O (22 August 2017); https://doi.org/10.1117/12.2271783
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Open source software

Image processing

Video

Digital cameras

Eye

Java

Photography

RELATED CONTENT

Framing photos in the digital dark age towards a...
Proceedings of SPIE (August 01 2021)
185-deg. ultrawide fish eye lens
Proceedings of SPIE (September 07 1998)
Multimedia approach to social research
Proceedings of SPIE (December 15 2003)
Digital stills
Proceedings of SPIE (March 14 1995)

Back to Top