Paper
5 March 2018 Optimisation of a polygon mirror-based spectral filter for swept source optical coherence tomography (SS-OCT)
Author Affiliations +
Proceedings Volume 10591, 2nd Canterbury Conference on OCT with Emphasis on Broadband Optical Sources; 105910V (2018) https://doi.org/10.1117/12.2283034
Event: Second Canterbury Conference on Optical Coherence Tomography, 2017, Canterbury, United Kingdom
Abstract
Medical imaging using Optical Coherence Tomography (OCT) provides clinicians with 3D, high resolution reconstructions of microscopic structures, in depth. It has been initially developed for ophthalmology, in order to scan the retinas of patients to diagnose illness. The quality of the images depends upon their axial and lateral resolutions and the properties of the light being used. Research using a polygon mirror (PM) as a spectral filter in Swept Source OCT (SS-OCT) has resulted in a variety of different experimental arrangements. Although the application of PM-based SS-OCT sources has been successfully demonstrated, the combination of their components’ fundamental properties and the overall impact they have on imaging performance is rarely reported. A more detailed examination of these properties would lead to a full description of their operation and to the best methods to employ if system performance is to be maximised. This work presents our current findings of on-going research into the optimisation of PM-based SS-OCT systems. A swept source spectral filter, consisting of a collimator, a transmission grating, a two-lens telescope and an off-axis PM with an end reflector mirror has been evaluated experimentally and compared with theoretical predictions. The system’s performance has been compared for two different fibre collimators. Although the beam width on the grating is different for each of the two collimators, the spot size at the PM facet is made the same by selecting appropriate focal lengths. An improvement in the signal roll-off at the interferometer output of ~1.0 dB/mm was obtained when using a 3.4 mm collimator compared to a 1.5 mm collimator.
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Michael Everson, Virgil-Florin Duma, and George Dobre "Optimisation of a polygon mirror-based spectral filter for swept source optical coherence tomography (SS-OCT)", Proc. SPIE 10591, 2nd Canterbury Conference on OCT with Emphasis on Broadband Optical Sources, 105910V (5 March 2018); https://doi.org/10.1117/12.2283034
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Collimators

Optical filters

Telescopes

Space telescopes

Mirrors

Optical coherence tomography

Signal detection

RELATED CONTENT


Back to Top