Paper
8 July 2022 Research on automatic calibration system and measurement method of high precision photoelectric encoder
Author Affiliations +
Abstract
High precision photoelectric angle encoder is a key component of intelligent angle measuring with strategic significance. A special fixture and adjustment measurement method is proposed, which can effectively solve many problems such as eccentricity, tower difference error and rotation interference caused by the direct fixation of rotating shaft (mover) and driving shaft during measurement. An automatic calibration system is also setup, which can realize many measurement schemes, such as direct calibration of turntable, polyhedral prism calibration and permutation comparison calibration. The measurement accuracy of the system is verified by comparison experiments and repeatability experiments. The measurement uncertainty of the optimal angular division error can reach 0.15 "(k = 2).
© (2022) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Fangfang Liu, Yu Ren, and Feng Zhang "Research on automatic calibration system and measurement method of high precision photoelectric encoder", Proc. SPIE 12282, 2021 International Conference on Optical Instruments and Technology: Optoelectronic Measurement Technology and Systems, 122820G (8 July 2022); https://doi.org/10.1117/12.2616525
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Autocollimators

Data acquisition

Measurement devices

RELATED CONTENT

Recent developments in nanoradian-angle metrology
Proceedings of SPIE (September 07 2017)
Universal dynamic goniometer for rotary encoders
Proceedings of SPIE (June 26 2017)
Laser optical displacement system
Proceedings of SPIE (April 20 1995)

Back to Top