Abstract
The goal of our research program is to develop competitive and sandwich fluoroimmunoassays with high sensitivity and fast response time, that do not require external reagents. Our approach to this problem is to employ an optical immunoassay based on total internal reflection fluorescence (TIRF). Specifically, monoclonal antibodies are immobilized on a planar waveguide. Total internal reflection of light in the planar waveguide sets up an evanescent field which extends about 2000 angstroms from the interface. In the competitive immunoassay, a fluorescent label is coupled to a small synthetic antigen which is packaged with the antibody. In the absence of analyte, the fluorescently labeled antigen binds to the antibody and is excited by the evanescent field. Upon the addition of analyte, the fluorescently labeled antigen molecules are displaced by unlabeled antigen molecules and diffuse out of the evanescent field. In the sandwich assay, a primary or `capture' antibody is immobilized on the planar waveguide, and a secondary or `tracer' antibody (which is labeled with a fluorescent dye) is added to the bulk solution. In the absence of analyte, the tracer antibody remains in solution and very little fluorescence is observed. However, upon addition of analyte, a `molecular sandwich' is formed on the waveguide, composed of: (1) the capture antibody; (2) the analyte; and (3) the tracer antibody. Once this sandwich forms, the tracer antibody is within the evanescent field and fluoresces. Fluorescence emission is detected by a charged- coupled device (CCD). Using this approach, we have developed a prototype immunosensor for the detection of human chorionic gonadotropin (hCG). This device meets our design goals and exhibits a sensitivity of 0.1 - 1 pmolar.
© (1993) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
James N. Herron, Karin D. Caldwell, Douglas A. Christensen, Shellee Dyer, Vladimir Hlady, P. Huang, V. Janatova, Hiabo K. Wang, and A. P. Wei "Fluorescent immunosensors using planar waveguides", Proc. SPIE 1885, Advances in Fluorescence Sensing Technology, (18 May 1993); https://doi.org/10.1117/12.144735
Lens.org Logo
CITATIONS
Cited by 18 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Luminescence

Waveguides

Planar waveguides

Silica

Interfaces

Monoclonal antibodies

Molecules

Back to Top