Paper
20 October 1993 NICMOS flight hardware 256 x 256 MCT detector array configuration
John G. Poksheva, Leonard R. Tocci, Mark C. Farris, Stephanie E. Tallarico
Author Affiliations +
Abstract
Features of the flight hardware version of the NICMOS 256 X 256 mercury-cadmium- telluride (MCT) detector array for the Hubble Space Telescope (HST) are presented and described. Detector flowdown requirements for flight production are reviewed and discussed. Detector cross section and array architecture features are analyzed in relation to quantum efficiency and crosstalk behavior. Features of the charge integration scheme employed are analyzed in assessing dynamic range.
© (1993) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
John G. Poksheva, Leonard R. Tocci, Mark C. Farris, and Stephanie E. Tallarico "NICMOS flight hardware 256 x 256 MCT detector array configuration", Proc. SPIE 1946, Infrared Detectors and Instrumentation, (20 October 1993); https://doi.org/10.1117/12.158668