PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.
A method based on a quartz crystal microbalance (QCM) was used for the first time to analyze oil quality on line. When the QCM is immersed in the oil, the resonant frequency will change according to the change of viscosity, density of oil on the crystal electrode. According to this principle, Quartz Crystal Microbalance (QCM) with temperature sensor is a novel test technique that allows for the on-line, real- time analysis of quality of the oil. In this article the principle and measuring device of QCM as oil analysis sensor are described. The key design of the hardware of this system is given.
Jianfeng Zhang andYouyun Zhang
"Determination of oil quality using a quartz crystal microbalance", Proc. SPIE 4414, International Conference on Sensor Technology (ISTC 2001), (14 September 2001); https://doi.org/10.1117/12.440147
ACCESS THE FULL ARTICLE
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.
The alert did not successfully save. Please try again later.
Jianfeng Zhang, Youyun Zhang, "Determination of oil quality using a quartz crystal microbalance," Proc. SPIE 4414, International Conference on Sensor Technology (ISTC 2001), (14 September 2001); https://doi.org/10.1117/12.440147