The near infrared spectral region (NIR) is useful in many applications. These include agriculture, the food and chemical industry, and textile and medical applications. In this region, spectral reflectance measurements are currently made with conventional spectrophotometers. These instruments are expensive since they use a diffraction grating to obtain monochromatic light. In this work, we present a multispectral imaging based technique for obtaining the reflectance spectra of samples in the NIR region (800 - 1000 nm), using a small number of measurements taken through different channels of a conventional CCD camera. We used methods based on the Wiener estimation, non-linear methods and principal component analysis (PCA) to reconstruct the spectral reflectance. We also analyzed, by numerical simulation, the number and shape of the filters that need to be used in order to obtain good spectral reconstructions. We obtained the reflectance spectra of a set of 30 spectral curves using a minimum of 2 and a maximum of 6 filters under the influence of two different halogen lamps with color temperatures Tc1 = 2852K and Tc2 = 3371K. The results obtained show that using between three and five filters with a large spectral bandwidth (FWHM = 60 nm), the reconstructed spectral reflectance of the samples was very similar to that of the original spectrum. The small amount of errors in the spectral reconstruction shows the potential of this method for reconstructing spectral reflectances in the NIR range.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Meritxell Vilaseca, Jaume Pujol, and Montserrat Arjona "NIR spectrophotometric system based on a conventional CCD camera", Proc. SPIE 5011, Machine Vision Applications in Industrial Inspection XI, (22 May 2003); https://doi.org/10.1117/12.474007
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Optical filters

Nonlinear filtering

Near infrared

Reflectivity

Principal component analysis

Technetium

Cameras

Back to Top