20 April 2005 Analysis of factors that affect DQE in digital mammography
Author Affiliations +
Abstract
The international standard IEC 62220-1 about DQE measurement of digital X-ray equipment was published in 2003, but mammography systems aren’t applied to this IEC standard because the factor affect measurement is complicated. Especially, the influence to the pre-sampling MTF by edge method when X-ray beam is oblique to detector. The influence of nonuniformity of x-ray intensity by the heel effect on digital Wiener spectrum (WS) doesn’t become clear. A 0.1mm-thick tungsten edge was imaged in the position where X-ray beam was perpendicular to detector plane and in 6cm from chest wall, respectively. And the pre-sampling MTFs were obtained from these edge images. The calculation area of the digital WS within irradiation area was moved in parallel direction to X-ray tube axis, and the digital WS were calculated. The pre-sampling MTFs and the digital WS are calculated by the method based on the IEC proposal. We used MAMMOMAT3000(SIEMENS), MGU-100B(TOSHIBA), M-IV(LORAD) and Senographe DMR+(GE) as X-ray generator. Images were obtained by FCR PROFECT CS (Fujifilm medical). In all equipments and both arrangement directions of the edge test device, pre-sampling MTFs are almost the same, even if the arrangement places of the edge test device varied. In all equipments, when the calculation area was moved about 10cm, the digital WS of the anode side was higher 7.2-17.9% than those of the cathode side. It was found that the dose of anode side was lower about 20% than cathode side from the profile of an exposure image. We think that digital WS modified the nonuniformity of the dose by the heel effect is obtained by multiplying the digital WS by the compensation coefficient obtained by the dose profile, in low spatial frequency.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Miho Takamura, Akiko Higaki, and Yoshie Kodera "Analysis of factors that affect DQE in digital mammography", Proc. SPIE 5745, Medical Imaging 2005: Physics of Medical Imaging, (20 April 2005); https://doi.org/10.1117/12.595038
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Modulation transfer functions

Chest

X-rays

Sensors

X-ray detectors

Digital mammography

Tungsten

Back to Top