Paper
15 November 2011 Compatibility design for time grating interface based on forecasting method
Fangyan Zheng, Ziran Chen, Jin Lu, Chun Dong
Author Affiliations +
Proceedings Volume 8321, Seventh International Symposium on Precision Engineering Measurements and Instrumentation; 832108 (2011) https://doi.org/10.1117/12.903659
Event: Seventh International Symposium on Precision Engineering Measurements and Instrumentation, 2011, Yunnan, China
Abstract
Time grating is a novel displacement sensor which employs time to measure space. A new predictive method for predicting the dynamic angular displacement of CNC rotary table is presented with time series. In addition, feedback interface for rotary transformer is designed to update data speed for time grating in the measurement process. Experiment results prove that forecast error for acceleration range from -0.00026″/ms2 to 0.00028″/ms2, and forecast angular displacement error is within ±2″.
© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Fangyan Zheng, Ziran Chen, Jin Lu, and Chun Dong "Compatibility design for time grating interface based on forecasting method", Proc. SPIE 8321, Seventh International Symposium on Precision Engineering Measurements and Instrumentation, 832108 (15 November 2011); https://doi.org/10.1117/12.903659