Paper
16 August 2013 Research on calculation of cathode electron scattering radius in the generation III image intensifier
Yaojin Cheng, Feng Shi, Lei Yan, Zhipeng Hou, Hongli Shi, Feng Liu, Min Li
Author Affiliations +
Proceedings Volume 8912, International Symposium on Photoelectronic Detection and Imaging 2013: Low-Light-Level Technology and Applications; 891212 (2013) https://doi.org/10.1117/12.2034314
Event: ISPDI 2013 - Fifth International Symposium on Photoelectronic Detection and Imaging, 2013, Beijing, China
Abstract
In the proximity focusing imaging system, the clear degree of images characterized by electronic scattering radius which could directly decide the resolution. In generation Ⅲ image intensifier, ion barrier film on the input of MCP is a serious influence factor on device resolution due to its electron scattering process. In this paper the electronic scattering radius would calculate at the single electron scattering, large electron scattering, and having ion barrier film electron scattering. Through comparing, it is found that the electron scattering radius is significantly larger at having an ion barrier film on the input of MCP. The results of calculation show that reducing the gap cathode-MCP and increasing the cathode voltage could reduce electron scattering radius, so as to improve the resolution of generation Ⅲ image intensifier.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yaojin Cheng, Feng Shi, Lei Yan, Zhipeng Hou, Hongli Shi, Feng Liu, and Min Li "Research on calculation of cathode electron scattering radius in the generation III image intensifier", Proc. SPIE 8912, International Symposium on Photoelectronic Detection and Imaging 2013: Low-Light-Level Technology and Applications, 891212 (16 August 2013); https://doi.org/10.1117/12.2034314
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Scattering

Image intensifiers

Microchannel plates

Modulation transfer functions

Ions

Image resolution

Ion beam finishing

RELATED CONTENT

New half film method for measuring Al2O3 film MTF of...
Proceedings of SPIE (October 15 2012)
Veiling Glare In The ITT F4113 Image Intensifier
Proceedings of SPIE (February 01 1989)
Development of the 12 inch high definition x ray image...
Proceedings of SPIE (April 01 1993)
Image Intensifier Tubes
Proceedings of SPIE (March 01 1974)

Back to Top