SUBSCRIPTIONS & PRICING
GENERAL INFORMATION
Logged Out Log In
Semi-automatic detection of Gd-DTPA-saline filled capsules for colonic transit time assessment in MRI
Proc. SPIE 6914, 69143K (2008); http://dx.doi.org/10.1117/12.769867
Sunday 17 February 2008
San Diego, CA, USA
Medical Imaging 2008: Image Processing
Joseph M. Reinhardt, Josien P. W. Pluim
Functional gastrointestinal disorders result in a significant number of consultations in primary care facilities. Chronic constipation and diarrhea are regarded as two of the most common diseases affecting between 2% and 27% of the population in western countries1-3. Defecatory disorders are most commonly due to dysfunction of the pelvic floor or the anal sphincter. Although an exact differentiation of these pathologies is essential for adequate therapy, diagnosis is still only based on a clinical evaluation1. Regarding quantification of constipation only the ingestion of radio-opaque markers or radioactive isotopes and the consecutive assessment of colonic transit time using X-ray or scintigraphy, respectively, has been feasible in clinical settings4-8. However, these approaches have several drawbacks such as involving rather inconvenient, time consuming examinations and exposing the patient to ionizing radiation. Therefore, conventional assessment of colonic transit time has not been widely used. Most recently a new technique for the assessment of colonic transit time using MRI and MR-contrast media filled capsules has been introduced9. However, due to numerous examination dates per patient and corresponding datasets with many images, the evaluation of the image data is relatively time-consuming. The aim of our study was to develop a computer tool to facilitate the detection of the capsules in MRI datasets and thus to shorten the evaluation time. We present a semi-automatic tool which provides an intensity, size10, and shape-based11,12 detection of ingested Gd-DTPA-saline filled capsules. After an automatic pre-classification, radiologists may easily correct the results using the application-specific user interface, therefore decreasing the evaluation time significantly.
© 2008 COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
History
Online Mar 11, 2008
Digital Object Identifier
Citation
Christian Harrer, Sonja Kirchhoff, Andreas Keil, Chlodwig Kirchhoff, Thomas Mussack, Andreas Lienemann, Maximilian Reiser and Nassir Navab, "Semi-automatic detection of Gd-DTPA-saline filled capsules for colonic transit time assessment in MRI",
Proc. SPIE 6914, 69143K (2008); http://dx.doi.org/10.1117/12.769867
DOWNLOAD ARTICLE
RELATED CONTENT
For access to fully linked references, you need to log in.















This Publication
Google Scholar
PubMed