6 July 2018 JWST mirror and actuator performance at cryo-vacuum
Erin M. Wolf, Benjamin B. Gallagher, J. Scott Knight, Taylor S Chonis, Joseph F. Sullivan, Koby Z. Smith, Andrew Rudeen, Kevin Babcock, Bruce Hardy, Allison Barto, Eric Coppock, Clinton R. Davis
Author Affiliations +
Abstract
The James Webb Space Telescope (JWST) telescope’s Secondary Mirror Assembly (SMA) and eighteen Primary Mirror Segment Assemblies (PMSAs) are each actively controlled in rigid body position via six hexapod actuators. Each of the PMSAs additionally has a radius of curvature actuator. The mirrors are stowed to the mirror support structure to survive the launch environment and then must be deployed 12.5 mm to reach the nominally deployed position before the Wavefront Sensing & Control (WFSC) alignment and phasing process begins. JWST requires testing of the full optical system in a Cryogenic Vacuum (CV) environment before launch. The cryo vacuum test campaign was executed in Chamber A at the Johnson Space Center (JSC) in Houston Texas. The test campaign consisted of an ambient vacuum test, a cooldown test, a cryo stable test at 65 Kelvin, a warmup test, and finally a second ambient vacuum test. Part of that test campaign was the functional and performance testing of the hexapod actuators on the flight mirrors. This paper will describe the testing that was performed on all 132 hexapod and radius of curvature actuators. The test campaign first tests actuators individually then tested how the actuators perform in the hexapod system. Telemetry from flight sensors on the actuators and measurements from external metrology devices such as interferometers, photogrammetry systems and image analysis was used to demonstrate the performance of the JWST actuators. The mirror move commanding process was exercised extensively during the JSC CV test and many examples of accurately commanded moves occurred. The PMSA and SMA actuators performed extremely well during the JSC CV test, and we have demonstrated that the actuators are fully functional both at ambient and cryo temperatures and that the mirrors will go to their commanded positions with the accuracy needed to phase and align the telescope.
Conference Presentation
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Erin M. Wolf, Benjamin B. Gallagher, J. Scott Knight, Taylor S Chonis, Joseph F. Sullivan, Koby Z. Smith, Andrew Rudeen, Kevin Babcock, Bruce Hardy, Allison Barto, Eric Coppock, and Clinton R. Davis "JWST mirror and actuator performance at cryo-vacuum", Proc. SPIE 10698, Space Telescopes and Instrumentation 2018: Optical, Infrared, and Millimeter Wave, 1069808 (6 July 2018); https://doi.org/10.1117/12.2312872
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Actuators

Mirrors

James Webb Space Telescope

Phase shifts

Cryogenics

Space telescopes

Observatories

RELATED CONTENT

The JWST science instrument payload: mission context and status
Proceedings of SPIE (September 04 2015)
Development status of the Millimetron Space Observatory
Proceedings of SPIE (January 01 1900)
MIRI telescope simulator (MTS) folding mirrors
Proceedings of SPIE (September 12 2007)
Observatory alignment of the James Webb Space Telescope
Proceedings of SPIE (September 21 2012)

Back to Top