Abstract
Augmented reality (AR) display having vergence-accommodation conflict (VAC) problem which causes dizziness and motion sickness to viewers. It occurs because of the way of displaying a stereoscopic image. This is a severe disadvantage and must be managed for the popularization of AR. Implementing an integral imaging into the AR system can solve this VAC problem, but this system still has a limited depth problem originated from integral imaging. By using focus tunable lens array instead of an ordinary fixed one, the depth limitation of the integral imaging system can be overcome. Electrowetting lens can be implemented into focus tunable microlens array for AR integral imaging with the advantage of small form factor, fast response time and precise focal length control. By using a hexagonal arrangement and solid lens attach, the lens array with high fill-factor for AR display is fabricated. Its specification is well optimized for AR display and focus tunable integral imaging display is constructed with this lens array. Micro display with small sized pixel is loaded with elemental images, and the tunable lens array makes an image of object inside the panel which has a depth of few centimeters. And magnifying lens and beam splitter makes meter scale object into the air. By adjusting the applied voltage for the liquid lens array, the position of central depth plan can vary from tens of centimeters to meter scale, which satisfies enough range for typical AR usage. With the system, objects with various distant can be displayed clearly with some technical implementation.
Conference Presentation
© (2020) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Cheoljoong Kim, Dooseub Shin, Gyohyun Koo, and Yong Hyub Won "Depth enhancement of integral imaging AR display with an electrowetting microlens array", Proc. SPIE 11304, Advances in Display Technologies X, 113040A (26 February 2020); https://doi.org/10.1117/12.2546064
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Integral imaging

Augmented reality

Liquid lenses

Microlens array

3D displays

RELATED CONTENT

Elemental images for integral-imaging display
Proceedings of SPIE (May 17 2013)
Slanted liquid microlens array by using diffuser
Proceedings of SPIE (March 14 2016)
3D augmented reality with integral imaging display
Proceedings of SPIE (June 01 2016)
Long viewing distance autostereoscopic display
Proceedings of SPIE (March 22 2005)
Improved resolution in far-field integral imaging
Proceedings of SPIE (May 10 2012)

Back to Top