Paper
1 December 1989 Design Principles And Instrumentation For Step-Scan FTIR
Christopher J. Manning, Richard A. Palmer
Author Affiliations +
Proceedings Volume 1145, 7th Intl Conf on Fourier Transform Spectroscopy; (1989) https://doi.org/10.1117/12.969610
Event: Seventh International Conference on Fourier and Computerized Infrared Spectroscopy, 1989, Fairfax, VA, United States
Abstract
Step-scan, or step-by-step data collection in optical interferometry historically preceeded the rapid-scan method currently favored by commercial FTIR instrument manufacturers. Although rapid-scan data collection with opto-electronic sampling control has clearly been the key to the dramatic revival of FTIR, and of infrared spectroscopy in general, there are some experiments for which a return to step-scan techniques is a definite advantage. These include particularly experiments in which time resolution in the range of rapid-scan Fourier modulation periods is desirable. Step-scan FTIR differs from rapid-scan FTIR in the control of the mirror position and the timing of data collection. The rapid-scan mode involves moving the mirror continuously, and triggering data collection at evenly spaced intervals of the HeNe reference laser interference pattern. A particular advantage of rapid scanning is that minor fluctuations in the velocity of the mirror are compensated for during sampling. In contrast, with step-scan operation the mirror is stopped at, or vibrated about, each data collection point. This has the effect of uncoupling the spectral multiplexing from any temporal aspects of the experiment and makes step-scanning applicable to a wide range of dynamic spectroscopy. However, fluctuations in the mirror position are not easily compensated for and contribute to noise in the transformed spectra. The minimization of such sampling errors is the central challenge of step-scan interferometry.
© (1989) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Christopher J. Manning and Richard A. Palmer "Design Principles And Instrumentation For Step-Scan FTIR", Proc. SPIE 1145, 7th Intl Conf on Fourier Transform Spectroscopy, (1 December 1989); https://doi.org/10.1117/12.969610
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Mirrors

Phase modulation

Modulation

FT-IR spectroscopy

Amplitude modulation

Signal to noise ratio

Sensors

RELATED CONTENT

Fourier Transform Spectroscopy In The Submillimeter Region
Proceedings of SPIE (October 29 1981)
High-speed resonant FTIR spectrometer
Proceedings of SPIE (May 17 2012)
Spectroscopy With Triangular Modulation
Proceedings of SPIE (December 01 1989)
The Effect Of The Zeros Of Transfer Function On System...
Proceedings of SPIE (October 19 1987)
Advantages Of Flexible Scanning
Proceedings of SPIE (August 16 1983)

Back to Top