Paper
1 April 1992 Using the decay of intrinsic tyrosine fluorescence of core particles to monitor conformational changes
David W. Brown, Louis J. Libertini, Enoch W. Small
Author Affiliations +
Abstract
This paper examines the effect of ionic strength on the decay of intrinsic tyrosine fluorescence from chromatin core particles. All measured decays were complex, showing at least four components. At 0.1 M salt the average lifetime was approximately 0.5 ns with 67% of the emitting tyrosines having lifetimes on the order of 0.3 ns, 30% near 0.8 ns, and the remainder around 1.8 ns. The average lifetime increases continuously by about 50% as the ionic strength is decreased to very low values. The decrease was characterized by a small shift in contributions from components with approximately 0.3 ns lifetimes mainly to components with lifetimes on the order of 1.8 ns. The rate of change was greatest over the range of the low-salt transition ([Na]> 0.5 mM). As the salt concentration was increased beyond 0.1 M a large increase in average lifetime is observed as the histone proteins within the core particle dissociate from the DNA. The average lifetime increased to a maximum of approximately 1.6 ns due to a large decrease in contribution from components with approximately 0.3 ns lifetimes accompanied by the appearance of components with lifetimes mainly from approximately 1.8 to approximately 4.0 ns. Throughout the range of salt examined the changes in average decay lifetime paralleled changes in the steady-state fluorescence intensity. This agreement indicates that all tyrosines contributing to the fluorescence at very high and very low salt also contribute at intermediate (0.1 M) salt. It is not necessary, as suggested by others, to consider some tyrosines to be statically quenched in the intact core particle.
© (1992) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
David W. Brown, Louis J. Libertini, and Enoch W. Small "Using the decay of intrinsic tyrosine fluorescence of core particles to monitor conformational changes", Proc. SPIE 1640, Time-Resolved Laser Spectroscopy in Biochemistry III, (1 April 1992); https://doi.org/10.1117/12.58277
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Particles

Luminescence

Biochemistry

Quantum efficiency

Laser spectroscopy

Energy transfer

Lamps

Back to Top