Paper
30 September 1994 Contamination control and material screening for the extreme ultraviolet coronal diagnostic spectrometer on SOHO
Barry J. Kent, Bruce Miles Swinyard, Elizabeth L. Martin
Author Affiliations +
Abstract
The Coronal Diagnostic Spectrometer (CDS) to be flown on the Solar Heliospheric Observatory (SOHO) satellite makes use of both grazing and normal incidence optics operating in the extreme ultraviolet wavelength range from 15 to 80 nm. Its optical components include a Wolter Schwartzschild type 2 telescope and grazing and normal incidence reflective diffraction gratings. The instrument is thus highly sensitive to contamination both from particulate debris of a kind readily controlled by use of clean rooms, but also from offgassed and outgassed molecular species arising from materials used in clean room construction and from components within the instrument itself. We describe the contamination control protocol used to constrain the contamination, both particulate and molecular, to levels that will maintain the instrument performance for the expected duration of the SOHO mission. We also describe and report some results from a parallel activity in which we have screened materials for inclusion in CDS construction, by making use of a purpose built ultra high vacuum system to provide a contamination source and surface science diagnostics. In this apparatus material samples are held at elevated temperature to expel, in a controlled manner, outgas products which are allowed to contaminate previously characterized gold coated witness mirrors. The outgas products being monitored by residual gas analysis and a quartz crystal microbalance. The contaminated witness mirror surfaces are chemically characterized without breaking vacuum using X-ray photoelectron spectroscopy (XPS), and the change in reflectivity at ultraviolet wavelengths is also measured in the same apparatus.
© (1994) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Barry J. Kent, Bruce Miles Swinyard, and Elizabeth L. Martin "Contamination control and material screening for the extreme ultraviolet coronal diagnostic spectrometer on SOHO", Proc. SPIE 2210, Space Optics 1994: Space Instrumentation and Spacecraft Optics, (30 September 1994); https://doi.org/10.1117/12.188106
Lens.org Logo
CITATIONS
Cited by 6 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Contamination

Mirrors

Cadmium sulfide

Spectroscopy

Gold

Particles

Reflectivity

RELATED CONTENT

Contamination effects on EUV optics in the space environment
Proceedings of SPIE (November 01 1993)
At-wavelength diagnostics of EUV-optics
Proceedings of SPIE (May 18 2007)
Molecular contamination and the calibration of AXAF
Proceedings of SPIE (January 21 1993)
Hubble Space Telescope Contamination Analysis
Proceedings of SPIE (January 01 1987)
Particulate Contamination Control
Proceedings of SPIE (June 03 1987)

Back to Top