Abstract
This report documents system uncertainty, best practices, and process limitations for the real-time videogrammetry system developed by Metronor, ASA. The report describes the system and the tests used to establish its performance. It then documents the test result and draws conclusions. An uncertainty of 23.6 ppm within the 3.2 by 2.8 by 1.5-meter test volume was achieved with the baseline between the cameras parallel to the length of the target field. A slightly lower uncertainty of 18.5 ppm was achieved when the cameras were setup with their baseline normal to the length of the target field.Results suggest that the orientation of the camera baseline relative to the target field does not play a significant role when targets are more than 2 meters apart. Testing shows a significant dependence in system accuracy relative to the apex angle between the cameras and the targets. When the apex angle was between 60 degrees and 95 degrees the performance specification was met. Conclusions drawn from a series of two-sample F-tests of RSS error values establish that sampling a point more than three times does not significantly reduce its uncertainty. This result is in part explained by the redundant fitting of the five-diode points on the light pen: the fitting effects an averaging process even on samples of one.
© (1998) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Scott C. Sandwith "Real-time videogrammetry uncertainty computation and test results", Proc. SPIE 3520, Three-Dimensional Imaging, Optical Metrology, and Inspection IV, (29 December 1998); https://doi.org/10.1117/12.334325
Lens.org Logo
CITATIONS
Cited by 9 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Cameras

Received signal strength

Imaging systems

Error analysis

Light emitting diodes

Calibration

Computing systems

RELATED CONTENT

Comparison of methods for 3D laser calibration
Proceedings of SPIE (March 15 1994)
Two-stage multiple cameras calibration
Proceedings of SPIE (December 01 1995)
Structure of a scene from two and three projections
Proceedings of SPIE (April 01 1991)
Performance evaluation of a vision dimension metrology system
Proceedings of SPIE (September 01 1991)

Back to Top