Paper
28 May 1999 Compact water-vapor Raman lidar
Savyasachee L. Mathur, Coorg R. Prasad
Author Affiliations +
Abstract
Continuous monitoring of atmospheric water vapor mixing ratio profiles, especially within the planetary boundary layer is required for weather assessment, global circulation models and atmospheric studies. Although conventional lidar techniques based on Raman scattering or differential absorption are capable of such measurements, they are usually large, expensive systems with high power lasers which pose eye safety problems. This paper describes a compact, cost effective, eye-safe, Raman lidar operating in the solar blind wavelength region that can be used for autonomous daytime and nighttime monitoring of water vapor in the lower atmosphere. The performance of the compact Raman lidar was simulated and also experimentally verified with a bread-board lidar. Daytime measurements of up to 2.5 km and nighttime measurements to over 3 km with 10% accuracy can be obtained with less than 10 minutes of averaging.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Savyasachee L. Mathur and Coorg R. Prasad "Compact water-vapor Raman lidar", Proc. SPIE 3707, Laser Radar Technology and Applications IV, (28 May 1999); https://doi.org/10.1117/12.351336