19 November 1985 Interlaboratory Comparison Of Multimode Optical Fiber Attenuation Measurement
Li Luo, Jiang Tongcun, Luo Ling, Yang Shao
Author Affiliations +
Abstract
Experiments show that optical fiber attenuation measurement systems used by many laboratories in China meet the requirements of standard measurement methods recommended by the International Telegraph and Telephone Consultative Committee (CCITT) and the International Electrotechnical Commission (IEC). A simplified, practical criterion for checking equilibrium mode distribution (EMD) has been obtained. Round-robin results show good agreement of attenuation measurement for six Chinese laboratories using this criterion.
© (1985) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Li Luo, Jiang Tongcun, Luo Ling, and Yang Shao "Interlaboratory Comparison Of Multimode Optical Fiber Attenuation Measurement", Proc. SPIE 0559, Fiber Optics: Short-Haul and Long-Haul Measurements and Applications III, (19 November 1985); https://doi.org/10.1117/12.949590