Paper
11 March 2008 Nonrigid registration of carotid ultrasound and MR images using a "twisting and bending" model
Nuwan D. Nanayakkara, Bernard Chiu, Abbas Samani, J. David Spence, Grace Parraga, Jagath Samarabandu, Aaron Fenster
Author Affiliations +
Abstract
Atherosclerosis at the carotid bifurcation resulting in cerebral emboli is a major cause of ischemic stroke. Most strokes associated with carotid atherosclerosis can be prevented by lifestyle/dietary changes and pharmacological treatments if identified early by monitoring carotid plaque changes. Plaque composition information from magnetic resonance (MR) carotid images and dynamic characteristics information from 3D ultrasound (US) are necessary for developing and validating US imaging tools to identify vulnerable carotid plaques. Combining these images requires nonrigid registration to correct the non-linear miss-alignments caused by relative twisting and bending in the neck due to different head positions during the two image acquisitions sessions. The high degree of freedom and large number of parameters associated with existing nonrigid image registration methods causes several problems including unnatural plaque morphology alteration, computational complexity, and low reliability. Our approach was to model the normal movement of the neck using a "twisting and bending model" with only six parameters for nonrigid registration. We evaluated our registration technique using intra-subject in-vivo 3D US and 3D MR carotid images acquired on the same day. We calculated the Mean Registration Error (MRE) between the segmented vessel surfaces in the target image and the registered image using a distance-based error metric after applying our "twisting bending model" based nonrigid registration algorithm. We achieved an average registration error of 1.33±0.41mm using our nonrigid registration technique. Visual inspection of segmented vessel surfaces also showed a substantial improvement of alignment with our non-rigid registration technique.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Nuwan D. Nanayakkara, Bernard Chiu, Abbas Samani, J. David Spence, Grace Parraga, Jagath Samarabandu, and Aaron Fenster "Nonrigid registration of carotid ultrasound and MR images using a "twisting and bending" model", Proc. SPIE 6914, Medical Imaging 2008: Image Processing, 691411 (11 March 2008); https://doi.org/10.1117/12.770337
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image registration

3D modeling

3D image processing

Magnetic resonance imaging

Image segmentation

3D acquisition

Rigid registration

Back to Top