Paper
15 July 2008 New technology and techniques for x-ray mirror calibration at PANTER
Michael J. Freyberg, Bernd Budau, Wolfgang Burkert, Peter Friedrich, Gisela Hartner, Kazutami Misaki, Martin Mühlegger
Author Affiliations +
Abstract
The PANTER X-ray Test Facility has been utilized successfully for developing and calibrating X-ray astronomical instrumentation for observatories such as ROSAT, Chandra, XMM-Newton, Swift, etc. Future missions like eROSITA, SIMBOL-X, or XEUS require improved spatial resolution and broader energy band pass, both for optics and for cameras. Calibration campaigns at PANTER have made use of flight spare instrumentation for space applications; here we report on a new dedicated CCD camera for on-ground calibration, called TRoPIC. As the CCD is similar to ones used for eROSITA (pn-type, back-illuminated, 75 μm pixel size, frame store mode, 450 μm micron wafer thickness, etc.) it can serve as prototype for eROSITA camera development. New techniques enable and enhance the analysis of measurements of eROSITA shells or silicon pore optics. Specifically, we show how sub-pixel resolution can be utilized to improve spatial resolution and subsequently the characterization of of mirror shell quality and of point spread function parameters in particular, also relevant for position reconstruction of astronomical sources in orbit.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Michael J. Freyberg, Bernd Budau, Wolfgang Burkert, Peter Friedrich, Gisela Hartner, Kazutami Misaki, and Martin Mühlegger "New technology and techniques for x-ray mirror calibration at PANTER", Proc. SPIE 7011, Space Telescopes and Instrumentation 2008: Ultraviolet to Gamma Ray, 701117 (15 July 2008); https://doi.org/10.1117/12.789853
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Calibration

Spatial resolution

Mirrors

Cameras

Telescopes

CCD cameras

RELATED CONTENT

eROSITA on SRG
Proceedings of SPIE (July 31 2014)
Upgrade of the x ray parallel beam facility XPBF 2.0...
Proceedings of SPIE (December 15 2020)
The ATHENA telescope and optics status
Proceedings of SPIE (August 29 2017)
Kirkpatrick-Baez x-ray optics: a review
Proceedings of SPIE (May 24 2011)
ESA optics technology preparation for IXO
Proceedings of SPIE (July 29 2010)

Back to Top