Paper
31 December 2008 An auto-focusing system for white light microscopic measurement
Ming Chang, Juti Rani Deka, Pei Jung Chen, Yu Kuan Chen, Changcai Cui
Author Affiliations +
Proceedings Volume 7130, Fourth International Symposium on Precision Mechanical Measurements; 71302T (2008) https://doi.org/10.1117/12.819660
Event: Fourth International Symposium on Precision Mechanical Measurements, 2008, Anhui, China
Abstract
With the rapid development of semiconductor technology the demand for high resolution measuring system is evolving at an ever-increasing pace. Microscope was initially used to detect the defect by connecting charge couple device (CCD) as an auxiliary device. In general, for microscopic measurement human eyes are used to focus on the sample. The adjustment depends on the operator's astute measurement ability, which affected the repeatability and accuracy of the readings. There is a need of high-speed microscope auto focusing system for industrial applications. The present investigation describes about the development of an autofocus system to carry out microscopic measurement more precisely and accurately with less time. The measurement system consists of a light source, two beam splitters, a movable sample stage and a Mirau's interferometer, a photo-detector and 8051 microcontroller (MCU89C51). The light reflected from the sample surface interferes with the light reflected from the reference and produce an interference pattern, which is imaged onto a CCD array. In the setup developed for the autofocus one extra beam splitter is placed in the path of interfered beam to the CCD. The beam splitter is placed at equal distances from the CCD and the photodetector. The focus position is determined from the voltage developed in the photo-detector due to the movement of sample stage of the microscope. The maximum voltage that obtained at the focus position is confirmed with the CCD image. Microcontroller is used to stop the controller at the focus position immediately once the sample stage reaches it. Software is developed to locate the maximum intensity position. The design may autofocus the interferometer within 4mm distance in 1 second. The auto-focusing not only provides enhanced repeatability and accuracy of the results at a faster rate but also minimizes operator involvement.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ming Chang, Juti Rani Deka, Pei Jung Chen, Yu Kuan Chen, and Changcai Cui "An auto-focusing system for white light microscopic measurement", Proc. SPIE 7130, Fourth International Symposium on Precision Mechanical Measurements, 71302T (31 December 2008); https://doi.org/10.1117/12.819660
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Charge-coupled devices

Beam splitters

Microscopes

Microcontrollers

Interferometers

Photodetectors

Sensors

RELATED CONTENT

Testing of a convergent optics system off axis using a...
Proceedings of SPIE (October 25 2011)
MROI's automated alignment system
Proceedings of SPIE (July 28 2008)
Color Laser Microscope
Proceedings of SPIE (April 01 1987)

Back to Top