4 August 2009 Method of partial vision temperature measurement by infrared thermometer
Author Affiliations +
Abstract
Based on the development of infrared thermometry all over the world, a problem has been pointed out. Whenever infrared thermometer has been used in measuring temperature, the field of full vision of target must be considered. Or else there will be a mistake. In the thesis, base on the theory of infrared thermometer, we analyze the reasons of the error. And we also deduce the theory equation of partial vision temperature measurement about infrared thermometry. In the process of deduction, because of the other influences are not considered; so we get the approximate equation of partial vision temperature measurement, based on measurement value we draw a compensatory curve to compensate the equation of infrared thermometry. The curve has reflected the compensating effect well. In the end, we analyze the reasons of error. We draw a conclusion that this method of partial vision temperature measurement is feasible. We discuss the error which caused by distance and get a feasible method to correct the error.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Guang-yong Jin, Ke-wei Huan, Xiao-guang Shi, and Chao Wang "Method of partial vision temperature measurement by infrared thermometer", Proc. SPIE 7383, International Symposium on Photoelectronic Detection and Imaging 2009: Advances in Infrared Imaging and Applications, 738304 (4 August 2009); https://doi.org/10.1117/12.835254
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Temperature metrology

Infrared radiation

Thermometry

Target detection

Thermography

Black bodies

Sensors

Back to Top