15 March 2013 Experimental assessment of error in an electromagnetically-tracked ultrasound-guided needle navigation system
Irene Ayukawa, Tamas Ungi, Keyvan Hashtrudi-Zaad, Gabor Fichtinger, Parvin Mousavi
Author Affiliations +
Abstract
Purpose: Electromagnetic (EM)-tracked ultrasound (US)-guided needle navigation systems have potential use in spinal interventions; however, an assessment of the accuracy of these systems is required. Analysis of these systems involves examining the overall error of the system and the error of its components. The purpose of this study is to estimate the error components in an EM-tracked US-guided needle navigation system, and to determine the relationships between them, specifically for evaluation of US probe calibration. Methods: The main parts of the experimental setup are the US probe, the tracker, and the needle. The system error is examined by imaging the tracked needle with the US probe. The positional tracking error is tested for multiple needle, probe and reference sensors using a 7×9 grid with 4 cm spacing between points. Needle calibration error is evaluated by pivot calibration. An upper bound for the probe calibration error is then estimated using a series of transformations between the tracker and the needle tip position. Results: For all experiments, the mean error and its standard deviation increase as a function of distance from the tracker. The upper-bound of the US probe calibration error is estimated to be 1.81 mm. Conclusion: Operating distance has significant impact on component error, and the optimal operating distance for the presented setup has been shown. Although US probe calibration error cannot be measured directly, its upper-bound has been estimated by assessing the errors in other components of the system.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Irene Ayukawa, Tamas Ungi, Keyvan Hashtrudi-Zaad, Gabor Fichtinger, and Parvin Mousavi "Experimental assessment of error in an electromagnetically-tracked ultrasound-guided needle navigation system", Proc. SPIE 8671, Medical Imaging 2013: Image-Guided Procedures, Robotic Interventions, and Modeling, 867124 (15 March 2013); https://doi.org/10.1117/12.2007160
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Calibration

Navigation systems

Error analysis

3D modeling

3D image processing

Electroluminescent displays

Back to Top