Paper
27 September 2016 Annular sub-aperture stitching interferometry testing for large-caliber aspheric
Pengfei Wu, Shuming Yang, Lin Sun, Pu Zhao, Zhuangde Jiang
Author Affiliations +
Proceedings Volume 9684, 8th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test, Measurement Technology, and Equipment; 968408 (2016) https://doi.org/10.1117/12.2241523
Event: Eighth International Symposium on Advanced Optical Manufacturing and Testing Technology (AOMATT2016), 2016, Suzhou, China
Abstract
An annular sub-aperture stitching interferometry testing is proposed for large-caliber aspheric lens testing, expanding the dynamic range of the interferometer, broadening the scope of the measurement, and reducing the cost of the measurement to a large extent without the use of compensating elements. The large-caliber aspheric is divided into several annular sub-apertures, and there are some overlapping areas between each two adjacent sub-apertures. When testing, the test aspheric is moved along the optical axis according to path planning so that the reference spherical shape and the test aspheric interest at points of common tangency to reduce the fringe density of the sub-aperture. However, in the process of moving the test optic, six DOF (degrees of freedom) misalignment errors will occur. According to the rigid body kinematics theory, the misalignment error separation model is established so that the misalignment factors can be calculated by the information of each overlapping regions. Then all sub-apertures are unified to the same reference with proper algorithm, and subsequently, misalignment error of the reference is removed by Zernike polynomial fitting, and the whole surface error is recovered. Simulation results are shown to demonstrate the feasibility of the method we developed. By analyzing the influence of the six DOF on the stitching result, the most important factor is obtained, and some measures are taken, that is, a measurement system combining two interferometers is designed, one of which is to measure the departures between the reference and the aspheric, and another to test the piston errors to be transmitted to the control system to improve the accuracy.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Pengfei Wu, Shuming Yang, Lin Sun, Pu Zhao, and Zhuangde Jiang "Annular sub-aperture stitching interferometry testing for large-caliber aspheric", Proc. SPIE 9684, 8th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test, Measurement Technology, and Equipment, 968408 (27 September 2016); https://doi.org/10.1117/12.2241523
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Aspheric lenses

Interferometers

Zernike polynomials

Optical spheres

Control systems design

Optical testing

Stitching interferometry

Back to Top