Paper
3 May 2016 Thermal system field performance predictions from laboratory and field measurements
Author Affiliations +
Abstract
Laboratory measurements on thermal imaging systems are critical to understanding their performance in a field environment. However, it is rarely a straightforward process to directly inject thermal measurements into thermal performance modeling software to acquire meaningful results. Some of the sources of discrepancies between laboratory and field measurements are sensor gain and level, dynamic range, sensor display and display brightness, and the environment where the sensor is operating. If measurements for the aforementioned parameters could be performed, a more accurate description of sensor performance in a particular environment is possible. This research will also include the procedure for turning both laboratory and field measurements into a system model.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Stephen D. Burks, David P. Haefner, Brian P. Teaney, and Joshua M. Doe "Thermal system field performance predictions from laboratory and field measurements", Proc. SPIE 9820, Infrared Imaging Systems: Design, Analysis, Modeling, and Testing XXVII, 98200U (3 May 2016); https://doi.org/10.1117/12.2224054
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Modulation transfer functions

Sensors

3D metrology

Performance modeling

Data modeling

Imaging systems

Electro optical modeling

RELATED CONTENT


Back to Top