1.IntroductionMultiphoton microscopy (MPM) has become the tool of choice for in vivo fluorescence imaging due to its superior penetration depth through scattering tissue. Although recent work using cortical excavation,1,2 regenerative amplifiers,3 or very long wavelength laser4 sources have sought to extend the maximum imaging depth of MPM up to -mm, routine MPM in mouse brain is typically limited to a few hundred microns. Micro-optics, including both gradient index (GRIN) lenses5,6 and microprisms,7,8 have extended the range of conventional MPM microscopes up to several millimeters. Most GRIN lenses used for MPM have been compound lenses in which a high (0.5 to 0.6) numerical aperture (NA) objective of less than pitch is glued to a lower-NA (0.1) relay lens. This is necessary in order to avoid focusing the short-pulse excitation laser inside the higher-NA material, which can result in bright fluorescence from the lens. However, this reduces the field-of-view by the ratio of the NAs of the relay and objective lenses (e.g., by for a 0.6 NA objective with a 0.1 NA relay). In addition, GRIN lenses suffer from severe optical aberrations, most significantly distortion and spherical aberration. While distortion acts to further limit the effective field-of-view, spherical aberration severely degrades the image quality. Early compound GRIN lenses for MPM had lateral resolutions of and axial resolutions as low as 12 to 15 μm.5,6 Recently, a compound lens consisting of a plano-convex, 0.8-NA objective lens coupled to a 0.45-NA GRIN relay lens has been shown to improve spherical aberration, with 1 μm lateral resolution and 4.4 μm axial resolution.9,10 This system has an outer diameter, including the metal sheath that contains the lens assembly, of 1.4 mm and therefore requires the removal of a significant amount of brain tissue over the region to be imaged. In addition, they are fairly expensive for a disposable device. In general, aberrations from GRIN lenses scale with pitch length, such that using shorter lenses results in reduced aberrations. Nonetheless, even using GRIN lenses slightly less than pitch can result in significant positive spherical aberration. Correction collars on commercial objective lenses typically add more positive spherical aberration to correct for the negative aberration induced by cover glasses, and therefore cannot be used alone to compensate for aberrations in GRIN lenses. However, we show here that a cover glass placed between the objective and a short GRIN lens can be used to compensate for the aberrations in the GRIN lens, with the correction collar of the objective used to rebalance any overcompensation by the cover glass. In addition, the system we present here is compact, easily integrated into standard MPM microscopes, and relatively inexpensive. 2.MethodsThe homebuilt multiphoton microscope has been previously described11,12 with the exception that the laser power was modulated by a Pockels cell (Model 350-80-LA-02 with a Model 302RM driver, ConOptics, Danbury, CT), and a 1-meter effective focal length lens was used to reduce the amount of overfilling of the back aperture, maximizing the laser power through the objective. Briefly, the microscope system was composed of a MaiTai Ti:sapphire mode-locked laser (Spectra-Physics, Mountain View, CA), a homebuilt microscope based on a BX51 upright microscope (Olympus America, Center Valley, PA) with homebuilt filter and detector housing, and an HC-125-02 photomultiplier tube (PMT; Hamamatsu Corporation, Bridgewater, NJ). We used a LUCPlanFLN 40X/0.6 NA objective with a correction collar for up to 2 mm of glass (Olympus America), a P-725.4-CD PIFOC QuickLock microscope objective piezoelectric translator with a E-665.CR controller (Physik Instruments GmbH & Co., Karlsruhe, Germany) for adjusting the vertical position of the objective, and an ASI M-2000 motorized stage (Applied Scientific Instruments, Inc., Eugene, OR) for positioning specimens under the lens. Scanning and image acquisition were controlled by ScanImage software.13 Positioning the GRIN lens assembly under the microscope objective was facilitated by a custom built lens holder bolted to the underside of the microscope nosepiece [Fig. 1(a)]. Our lens positioner was composed of a three-axis micromanipulator, a 2” kinetic platform mount with two tilt axes (Model KM100B, Thorlabs, Newton, NJ), and a machined aluminum arm with a GRIN lens mounting device [Fig. 1(b)]. A small steel mounting plate with a 3-mm clear aperture held the magnet on the GRIN lens assembly. Each of our GRIN lens assemblies consisted of a 500-μm-diameter GRIN lens, a small glass cover slip, and a magnetic washer [Fig. 1(b)]. GRIN lenses were supplied by GoFoton with specifications, as follows: 500-μm diameter ILH uncoated GRIN lens, 0.6NA, just under pitch, 150-μm working distance in glass at one end and 150-μm in water at the other end. The length of each lens was 1.689 mm. A cleaned #1.5 glass cover slip (Harvard Apparatus, Holliston, Massachusetts, USA), which is 170 μm thick, was glued to one end of the GRIN lens with Norland No. 73 optical adhesive (Norland Products, Inc., Cranbury, NJ) to partly compensate for spherical aberration inherent in GRIN lenses. Nickel-plated neodymium washers measuring thick (K&J Magnetics, Inc., www.kjmagnetics.com) were glued to the cover slips with Norland No. 73 optical adhesive (Norland Products, Inc., Cranbury, NJ). Using a magnet simplifies the design of the holding apparatus and results in a secure hold. An additional 1-mm cover glass was placed on top of the lens holder to provide additional negative spherical aberration. We characterized the point spread function (PSF) of our GRIN lens system using the second harmonic (SHG) signal from 100-nm barium titanate () nanoparticles (Sigma-Aldrich Corp, St. Louis, MO) incorporated into 2% agarose gel. Unlike fluorescent particles normally used for PSF measurements, SHG from particles does not photobleach and does not saturate. The SHG was collected using 886-nm laser excitation and a -nm band-pass filter (HQ430/100M-2P, Chroma Technology Corp., Rockingham, VT). A z-stack was acquired using the piezo translator to move the objective in either 0.5- or 1-μm steps. A custom MATLAB program was used to calculate the full-width-at-half-maximum (FWHM) for the lateral and axial directions from a z-stack containing a single nanoparticle. PSF measurements were acquired for the objective alone and coupled to either a GRIN lens without a cover slip or one with a cover slip attached and a 1-mm-thick piece of glass placed above the GRIN lens assembly. Measurements were taken of particles within the central 50% of the GRIN lens field-of-view. The optimal correction collar setting was determined empirically as the setting that produced the smallest PSF. For in vivo imaging, a GRIN lens was inserted into the cortex of a Thy1-YFPH transgenic mouse14 through a craniotomy, as previously described8 with a few exceptions as follows. All craniotomies were 2 mm posterior to bregma and 1 mm lateral to the midline. A 30-gauge needle was used to pierce and remove the dura, and sterile, physiological saline was applied to the craniotomy to keep the brain tissue hydrated. A blunted 23-gauge hypodermic needle was used to aspirate a column of cortical tissue without penetrating the corpus callosum. Aspiration was accomplished in stages beginning with advancing the needle tip 100 to 200 μm and then retracting the needle, irrigating the cavity with sterile saline, waiting for bleeding to stop, and then aspirating the fluid. More saline was applied if bleeding had not stopped. This procedure was repeated until a depth of 800 μm was reached. Once the bleeding was controlled and residual blood removed, the cavity was filled with sterile saline. All procedures involving mice were in accordance with protocols approved by the Yale Institutional Animal Care and Use Committee. For imaging, the anesthetized mouse was transferred in a surgical frame to the microscope stage under the prealigned GRIN lens. The stage was periodically moved up, and images were taken at each position until the desired depth was reached as evidenced by the appearance of fluorescently labeled pyramidal cells in the hippocampus. After reaching the desired implant depth, the piezo translator was used to change the plane of focus without moving the lens in the brain tissue. Images of neurons expressing YFP were acquired using 886-nm laser excitation and a 535-nm /50-nm band-pass filter (ET535/50M-2P, Chroma Technology Co.). 3.Results and DiscussionLateral and axial resolutions were compared between our optimized system and a nonoptimized system. Our optimized system included a GRIN lens with a glass cover slip attached and an additional 1-mm-thick cover glass placed between the microscope objective and GRIN lens. Our nonoptimized condition used an unmodified GRIN lens. Both the lateral and axial PSF were markedly smaller for our optimized configuration (Fig. 2). A diffraction-limited PSF would result in lateral and axial FWHMs of 556 nm and 3.99 μm, respectively. For the nonoptimized condition, the lateral and axial FWHM measurements had of and (), respectively, corresponding to 141% and 359% of the diffraction limit. In contrast, the lateral and axial FWHM values for our optimized system were and (), respectively, corresponding to 111% and 139% of the diffraction limit. For comparison, previously published results using a compound GRIN lens with a 0.8 NA plano-convex lens and 920 nm excitation resulted in PSFs with lateral and axial FWHM values of 606 nm and 2.8 μm, respectively, corresponding to 140% and 130% of the diffraction limit. Spherical aberration results in much greater broadening of the axial PSF than the lateral PSF. Given the ratio of axial:lateral FWHM for the optimized system, the residual deviation from diffraction-limited performance is likely due to coma, perhaps due in part to a small tilt of the GRIN lens relative to the optical axis. Chromatic aberration is not expected to have a large impact for multiphoton microscopy because the bandwidth of the excitation pulse is only , and the fluorescence signal is collected by large-area, nondescanned detectors. In vivo imaging of neurons in mouse hippocampus demonstrates the resolution of the GRIN lens assemblies. The 1.689-mm length of these lenses allows imaging of the hippocampus of mice with a lens assembly that is nearly flush with the skull of a mouse. Representative images of CA1 hippocampal neurons [Fig. 3(a)] and processes [Fig. 3(b)] show excellent resolution. As shown in Fig. 3a, the effective field-of-view is . The fluorescence intensity rolls off near the edges of the field-of-view due to increased off-axis aberrations and decreases in the effective numerical aperture. Previously, compound GRIN lenses used for MPM with 0.5 mm or smaller diameter have been limited to a field-of-view of only a few tens of microns.5,6 Moreover, we were able to resolve the presence of large dendritic spines in our images [Fig. 3(b), arrows]. 4.ConclusionsIn summary, compared to previous compound lenses with similar diameters, combining a short GRIN lens singlet with a cover glass and a correction collar for balancing spherical aberration has improved the lateral resolution almost twofold and the axial resolution almost threefold. The field-of-view is also improved by more than threefold. Although recent commercially available compound lenses using plano-convex objectives have achieved higher resolution, the simple system presented here comes closer to diffraction-limited performance, albeit with a lower NA. Furthermore, the markedly smaller diameter of these lenses results in less tissue displacement. In addition, the overall cost of the lens assemblies at the present time is of the cost of the commercially available compound lenses, making them essentially disposable lenses. AcknowledgmentsFunding for this work was provided by NSF CAREER Award DBI-0953902. We express our appreciation to Thomas Chia, Joseph Zinter, Nathan Gilfoy, and Amanda Foust (Yale University, New Haven, CT) for technical assistance. ReferencesA. Mizrahiet al.,
“High-resolution in vivo imaging of hippocampal dendrites and spines,”
J. Neurosci., 24
(13), 3147
–3151
(2004). http://dx.doi.org/10.1523/JNEUROSCI.5218-03.2004 JNRSDS 0270-6474 Google Scholar
D. A. Dombecket al.,
“Functional imaging of hippocampal place cells at cellular resolution during virtual navigation,”
Nat. Neurosci., 13
(11), 1433
–1440
(2010). http://dx.doi.org/10.1038/nn.2648 NANEFN 1097-6256 Google Scholar
P. TheerM. T. HasanW. Denk,
“Two-photon imaging to a depth of 1000 μm in living brains by use of a regenerative amplifier,”
Opt. Lett., 28
(12), 1022
–1024
(2003). http://dx.doi.org/10.1364/OL.28.001022 OPLEDP 0146-9592 Google Scholar
D. Kobatet al.,
“Deep tissue multiphoton microscopy using longer wavelength excitation,”
Opt. Express, 17
(16), 13354
–13364
(2009). http://dx.doi.org/10.1364/OE.17.013354 OPEXFF 1094-4087 Google Scholar
M. J. Leveneet al.,
“In vivo multiphoton microscopy of deep brain tissue,”
J. Neurophys., 91
(5), 1908
–1912
(2004). http://dx.doi.org/10.1152/jn.01007.2003 JONEA4 0022-3077 Google Scholar
J. C. Junget al.,
“In vivo mammalian brain imaging using one- and two-photon fluorescence microendoscopy,”
J. Neurophys., 92
(5), 3121
–3133
(2004). http://dx.doi.org/10.1152/jn.00234.2004 JONEA4 0022-3077 Google Scholar
T. H. ChiaM. J. Levene,
“Microprisms for in vivo multilayer cortical imaging,”
J. Neurophys., 102
(2), 1310
–1314
(2009). http://dx.doi.org/10.1152/jn.91208.2008 JONEA4 0022-3077 Google Scholar
T. H. ChiaM. J. Levene,
“In vivo imaging of deep cortical layers using a microprism,”
J. Visual. Exp.,
(2009) https://doi.org/www.jove.com/index/Details.stp?ID=1509 Google Scholar
R. P. J. BarrettoB. MesserschmidtM. J. Schnitzer,
“In vivo fluorescence imaging with high-resolution microlenses,”
Nat. Methods, 6
(7), 511
–561
(2009). http://dx.doi.org/10.1038/nmeth.1339 1548-7091 Google Scholar
B. Messerschmidtet al.,
“Novel concept of GRIN optical systems for high resolution microendoscopy. Part 1: Physical aspects,”
Proc SPIE, 6432 643202
(2007). http://dx.doi.org//10.1117/12.698831 Google Scholar
T. H. Chiaet al.,
“Multiphoton fluorescence lifetime imaging of intrinsic fluorescence in human and rat brain tissue reveals spatially distinct NADH binding,”
Opt. Express, 16
(6), 4237
–4249
(2008). http://dx.doi.org/10.1364/OE.16.004237 OPEXFF 1094-4087 Google Scholar
J. P. ZinterM. J. Levene,
“Maximizing fluorescence collection efficiency in multiphoton microscopy,”
Opt. Express, 19
(16), 15348
–15362
(2011). http://dx.doi.org/10.1364/OE.19.015348 OPEXFF 1094-4087 Google Scholar
T. A. Pologruto,
“Monitoring neural activity and [] with genetically encoded indicators,”
J. Neurosci., 24
(43), 9572
–9579
(2004). http://dx.doi.org/10.1523/JNEUROSCI.2854-04.2004 JNRSDS 0270-6474 Google Scholar
G. Fenget al.,
“Imaging neuronal subsets in transgenic mice expressing multiple spectral variants of GFP,”
Neuron, 28
(1), 41
–51
(2000). http://dx.doi.org/10.1016/S0896-6273(00)00084-2 NERNET 0896-6273 Google Scholar
|