Abstract

Purpose

Diagnosis and surveillance of thoracic aortic aneurysm (TAA) involves measuring the aortic diameter at various locations along the length of the aorta, often using computed tomography angiography (CTA). Currently, measurements are performed by human raters using specialized software for three-dimensional analysis, a time-consuming process, requiring 15 to 45 min of focused effort. Thus, we aimed to develop a convolutional neural network (CNN)-based algorithm for fully automated and accurate aortic measurements.

Approach

Using 212 CTA scans, we trained a CNN to perform segmentation and localization of key landmarks jointly. Segmentation mask and landmarks are subsequently used to obtain the centerline and cross-sectional diameters of the aorta. Subsequently, a cubic spline is fit to the aortic boundary at the sinuses of Valsalva to avoid errors related inclusions of coronary artery origins. Performance was evaluated on a test set of 60 scans with automated measurements compared against expert manual raters.

Result

Compared to training separate networks for each task, joint training yielded higher accuracy for segmentation, especially at the boundary (p < 0.001), but a marginally worse (0.2 to 0.5 mm) accuracy for landmark localization (p < 0.001). Mean absolute error between human and automated was ≤1 mm at six of nine standard clinical measurement locations. However, higher errors were noted in the aortic root and arch regions, ranging between 1.4 and 2.2 mm, although agreement of manual raters was also lower in these regions.

Conclusion

Fully automated aortic diameter measurements in TAA are feasible using a CNN-based algorithm. Automated measurements demonstrated low errors that are comparable in magnitude to those with manual raters; however, measurement error was highest in the aortic root and arch.

CC BY: © The Authors. Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
Sudeep Katakol, Timothy J. Baker, Zhangxing Bian, Yanglong Lu, Greg Spahlinger, Charles R. Hatt, and Nicholas S. Burris "Fully automated pipeline for measurement of the thoracic aorta using joint segmentation and localization neural network," Journal of Medical Imaging 10(5), 051810 (31 October 2023). https://doi.org/10.1117/1.JMI.10.5.051810
Received: 21 February 2023; Accepted: 24 October 2023; Published: 31 October 2023
Advertisement
Advertisement
KEYWORDS
Aorta

Education and training

Image segmentation

Arteries

Computed tomography

Anatomy

Standards development

Back to Top