Significance: Having a clear understanding of functional hyperemia is crucial for functional brain imaging and neurological disease research. Vasodilation induced by sensory stimulus propagates from the arterioles to the upstream pial arteries in a retrograde fashion. As retrograde vasodilation occurs briefly in the early stage of functional hyperemia, an imaging technique with a high temporal resolution is required for its measurement. Aim: We aimed to present an imaging method to measure stimulus-induced retrograde vasodilation in awake animals. Approach: An imaging method based on optical coherence tomography angiography, which enables a high-speed and label-free vessel diameter measurement, was developed and applied for the investigation. Results: The propagation speed of retrograde vasodilation of pial artery was measured in awake mice. Other characteristics of functional hyperemia such as temporal profile and amplitude of the vascular response were also investigated. Conclusions: Our results provide detailed information of stimulus-induced hemodynamic response in the brain of awake mice and suggest the potential utility of our imaging method for the study of functional hyperemia in normal and diseased brain. |
1.IntroductionNeurovascular coupling, a close interplay between neural activity and cerebral blood flow (CBF), regulates the blood supply of corresponding brain regions. The regulation is mediated by dilation and/or constriction of cerebral vessels. In order to effectively perfuse blood upon stimuli, the dilation of arterioles should be accompanied by the dilation of upstream pial arteries.1–3 Dilation of arterioles induced by neural activation propagates to the pial arteries in a retrograde fashion.2 A detailed mechanism of this coordinated vascular adjustment remains elusive; however, accumulating evidence indicates that such may be due to the signal transduction through endothelial and smooth muscle cell gap junctions in vessel walls.4,5 This hemodynamic response function of the brain is disrupted in pathological conditions. For example, attenuation of the CBF increase induced by a sensory stimulus has been reported in Alzheimer’s disease, hypertension, and ischemic stroke.1 The entire hemodynamic response process, including the amplitude of the response, could be affected by various pathological factors. Having a clear understanding of functional hyperemia both in normal and pathological conditions is critical for the interpretation of the signals of hemodynamically based imaging systems, such as blood-oxygen-level-dependent signal in functional magnetic resonance imaging.6 However, rapid hemodynamic changes, such as retrograde vasodilation, have not been properly investigated because of the insufficient temporal resolution of conventional imaging techniques.7,8 Although a high-speed optical intrinsic signal imaging (OISI) technique, with a frame rate of several tens of Hertz, could provide an indirect measurement of the propagation of vasodilation by estimating the changes in arterial hemoglobin concentration,9 a direct imaging technique with a high spatiotemporal resolution is required for the precise measurement of retrograde vasodilation. Two-photon laser scanning microscopy (TPLSM) was utilized for direct measurement of vessel diameter by scanning the focal spot of a laser across the width of the vessel.10,11 However, the point scanning geometry of TPLSM allows assessment of only the vessel segments within a narrow focal depth.12–14 Recently, optical coherence tomography angiography (OCTA) has been introduced in various functional imaging studies.15–17 OCTA provides a high spatial and temporal resolution three-dimensional (3-D) imaging of cerebral microvasculature and facilitates detailed hemodynamic analysis, taking into account the 3-D vessel geometry.17 In addition, OCTA enables accurate measurement of the vessel diameter without using any contrast agent injection, which makes this technology well suited for awake imaging studies and longitudinal imaging studies.18,19 Thus, in this study, we aimed to present the potential of OCTA for the measurement of stimulus-induced retrograde vasodilation in the awake mouse brain. 2.Materials and Methods2.1.Animal PreparationAll animal experimental procedures were approved by the Institutional Animal Care and Use Committee of Korea Advanced Institute of Science and Technology (KA2020-07). Male C57BL/6N mice () were used for this study. The experimental timeline is shown in Fig. 1(a). A chronic cranial window was implanted on the right barrel cortex, as previously described.20 A custom-made head holder was positioned over the window to minimize motion artifacts during imaging. After 2 weeks of recovery, all animals were trained for awake imaging. Specifically, after brief anesthesia with isoflurane (3%, v/v), the mouse was fixed by the head holder to two stationary vertical shafts and left to rest or move freely forward and backward on a treadmill. All whiskers at the left side of the animal were trimmed except E1 whisker, which was fixed at the tip of a piezo bender. The bender vibrated the whisker with a frequency of 10 Hz and with an amplitude of 2 to 3 mm at 10 mm from the mystacial pad. Of the four mice, one was used for the additional imaging session with an intraperitoneal administration of a mixture of ketamine and xylazine (100 and , respectively) to investigate the effects of anesthesia on hemodynamic response. During the experiment under anesthesia, body temperature was maintained at 36.5°C to 37.5°C. Heart rate and arterial oxygen saturation were also continuously monitored. 2.2.Imaging Setup and ProceduresFigure 1(b) shows the imaging setup for awake imaging. A swept-source OCT system with an A-line rate of 240 kHz was used, as previously described.17 The center wavelength of a wavelength-swept laser was , and the axial and transverse resolutions (full-width at half-maximum) of the system are both . An OISI system was designed to share the objective lens with OCT. For OISI, a green light emitting diode mounted with a band-pass filter () was used as a light source for the measurement of the changes in total hemoglobin concentration.9 A web camera was positioned facing the animals to observe their behavior. For OISI, two-dimensional (2-D) images were continuously acquired using a charge coupled device (CCD) camera for 10.5 s. During the acquisition, a 0.3-s whisker stimulus was applied 1.66 s after the onset of the acquisition where the stimulus consisted of a series of three sinusoidal whisker vibrations. A series of OISI images were generated by computing the fractional intensity difference between the baseline and response images. Seven sequential OISI images were averaged to produce a single averaged OISI image, and the resulting temporal resolution of the OISI was 0.25 s. Stimulus-induced changes in total hemoglobin concentration were observed in the OISI images of an awake resting mouse [Fig. 1(c) and Video 1]. We performed two different OCTA protocols as follows: OCTA-1, which was for identifying the geometric structure of pial vessels, and OCTA-2, which was for measuring rapid hemodynamic changes. For OCTA-1, a 3D-OCT angiogram was obtained at the region where the OISI was performed with a field of view (FOV) of . The 3D-OCT angiogram was composed of 1000 A-lines and 800 B-scans in the and directions, respectively. Each 2-D cross-sectional OCT angiogram was obtained by calculating the speckle decorrelation between a pair of consecutive OCT intensity cross-section images acquired at the same location.17,21 For OCTA-2, a series of 3-D intensity OCT data, where each volume consisting of 7 B-scans (400 A-lines/B-scan) imaged with a spacing over an FOV of , were continuously acquired for 7.58 s, with a volumetric rate of 86 volumes per s. Seven different locations across the width of a pial artery that showed a prominent response in the OISI images were scanned [indicated by white horizontal lines in the magnified inset in Fig. 2(c)]. A 3D-OCT angiogram was obtained by calculating the speckle decorrelation between two consecutive 3D-OCT intensity images, and the resulting temporal resolution of OCTA was 0.023 s. A whisker stimulus was applied for 0.3 s, which was initiated 1.66 s after the start of the image acquisition. To measure the average hemodynamic response, OCTA-2 was performed repeatedly (30 times). The entire imaging procedure was completed in 40 min. 2.3.Data AnalysisBy monitoring with the web camera, all imaging was performed when the animal was at rest without any movement to minimize motion induced hemodynamic variations. Video 2 shows representative cross-sectional OCT images of the awake mouse brain. For each angiogram acquired by OCTA-2, the average intensity projection was performed in the depth-direction (0 to from the cortical surface). Consequently, a series of 2-D en face OCT angiograms were obtained. Vessel diameter was measured as the width of the vessel from the depth-projected OCT angiograms, as previously described.17 To reduce the effect of arterial pulsatility, low-pass filtering with a cutoff frequency of 3 Hz was performed for each time course before the averaging procedure. The selected cutoff frequency was based on the normal heart rate of a mouse, which ranges from 400 to 700 beats per minute. 3.ResultsA representative CCD image of the mouse cranial window and the corresponding OISI images are shown in Figs. 2(a) and 2(b). As shown in the OISI images, the increasing total hemoglobin response propagated retrogradely from the arteriole (blue arrowhead) to the upstream pial artery (white arrowhead). The propagation speed of total hemoglobin response was obtained by measuring the time delay between the OISI signals at different locations with a temporal resolution of 0.25 s (Fig. S1 in the Supplementary Material). The mean propagation speed of total hemoglobin response for the four mice was . A depth-projected image of the 3D-OCT angiogram of the region indicated by the gray square in Fig. 2(a) is shown in Fig. 2(c), which was obtained by OCTA-1. A pial artery and its first-order branches are shaded in yellow. Temporal series of 3D-OCT angiograms (OCTA-2) were continuously acquired at the region where the retrograde propagation of total hemoglobin response was observed [magnified inset in Fig. 2(c)]. A detailed procedure of selecting the region of interest is described in Fig. S2 in the Supplementary Material. Each 3D-OCT angiogram consisted of seven cross-sectional OCT angiograms that were acquired at equally spaced locations (indicated as white lines in the magnified inset). To measure the propagation of vasodilation, pial artery diameters were measured at two different locations (Y3 and Y6), with a distance of . Although the distance was set to in Fig. 2(c), as an example, could be adjusted to multiples of the minimum distance, i.e., . A single segment of pial artery with no branch between the measurement locations (Y3 and Y6) was used for the propagation measurement. The left column in Fig. 2(d) with the two depth-projected OCT angiograms acquired for 7.58 s at Y3 and Y6, respectively, shows that the stimulus clearly increased the vessel diameters. The right column in Fig. 2(d) shows the average time course of the vessel diameter measured at Y3 and Y6, respectively; the arterial pulsatile effect (thin solid lines) was removed by the low-pass filtering (thick solid lines). Minimum–maximum normalization was performed for each low-pass filtered time course, and a time delay () between their peaks was measured [Fig. 2(e)]. The propagation speed of retrograde vasodilation was measured by dividing by . Figure 3(a) shows a depth-projected OCT angiogram of another mouse brain; the white square indicates the region where OCTA-2 was performed. The white arrow in the magnified view of the corresponding region indicates the direction of the propagation of total hemoglobin response, which was identified by OISI (Fig. S3 in the Supplementary Material). Figure 3(b) shows the average time courses of the vessel diameter measured at five different locations (Y2 to Y6), which are indicated by horizontal lines with different colors in Fig. 3(a). As shown in Fig. 3(b), the hemodynamic response was delayed with respect to the response measured at Y2 as the distance increases. The propagation speed of vasodilation was measured in four pial arteries from four mice [Fig. 3(c)]. The propagation speed was obtained for each animal using data obtained at different locations (which generate multiple pairs of and values) where the vessel boundaries were clearly identified. The propagation speed was measured as the slope of the regression line between and for each animal. The mean propagation speed of vasodilation for all animals was [Fig. 3(d)]. Note that the time difference of 0.01 s between the B-scan acquisitions at Y1 and Y6 due to the sequential imaging of a series of B-scans during the slow axis scan is sufficiently small limiting the error caused by this time difference to be negligible. Figure 3(e) shows the hemodynamic responses of four pial arteries from four mice. As shown in Fig. 3(e), the hemodynamic responses of the pial arteries were quite similar, especially during the initial dilation. The diameter of the vessels continuously increased and reached the maximum 1.3 to 2 s after the onset of the 0.3-s stimulus. The mean increase in the amplitude of the vasodilation was 7.5% of the baseline diameter. However, the hemodynamic response was altered under anesthesia as shown in Fig. 3(f). The mean change in diameter of the pial artery was smaller and slower in the anesthetic state (indicated by gray solid line) than in the awake state (indicated by black solid line). 4.DiscussionIn this study, we propose an imaging method for the measurement of the propagation of vasodilation during functional hyperemia in awake mice. Using 3D-OCT angiograms acquired continuously with a temporal resolution of 0.023 s, the propagation speed of vasodilation was measured by investigating the time delay between the maximum dilations at different locations along each pial artery. Our results showed that the mean propagation speed of vasodilation of the pial artery is . To the best of our knowledge, this is the first study to measure the propagation of vasodilation during functional hyperemia in awake animals. According to our result and the previous reports, the mean propagation speed of total hemoglobin concentration response measured by OISI ranges from 1.6 to .4,9 Although a comparison between the results of OCTA and OISI should be carefully interpreted because of the differences in the measurement principles, OCTA provides more direct assessment of stimulus-induced changes in vessel diameter. It is also noteworthy that the high temporal resolution of the proposed OCTA imaging scheme provided the measurement of the propagation of vasodilation within a pial artery segment without any branch. OCTA also enables the measurement of temporal profile and amplitude of the vascular response. Although vascular response depends on various factors, such as the location with respect to the activation site, vascular branching structure, and vessel size,14,22 our result showed that pial arteries with different locations and sizes in different animals have a relatively identical stimulus–response profile, especially during the initial dilation process. Furthermore, we showed an altered vascular response in an anesthetized condition.23,24 However, a detailed investigation on alterations in the propagation of vasodilation and other characteristics of hemodynamic responses under various anesthetized conditions is warranted. In conclusion, our proposed imaging method has a high spatial and temporal resolution and enables label-free measurement of stimulus-induced propagation of vasodilation in awake mice. Our results suggest that the method could be highly useful in the longitudinal monitoring of functional hemodynamic changes with a high spatiotemporal resolution in normal and diseased animal models. 5.AppendixIntensity OCT and OCTA B-scans acquired continuously at the same spatial location appear in Video 2, which shows intensity changes in the OCT B-scans. By computing the cross decorrelation between a pair of neighboring OCT B-scans (variations in a pair of consecutive intensity OCT B-scans), a single cross-sectional OCT angiogram was obtained. As shown in the series of intensity OCT B-scans and OCTA B-scans in Video 3, areas occupied by tissues other than vessels show almost no intensity change during the imaging of a series of B-scans and therefore show almost no OCTA signals. This indicates that the motion artifact occurred during the inter-B-scan time interval was negligibly small. The inter-B-scan time interval used for the study was 1.66 ms. DisclosuresThe authors declare no potential conflicts of interest with respect to the research, authorship, and/or publication of this article. AcknowledgementsThis work was supported by the National Research Foundation of Korea (Grant Nos. 2016M3C7A1913844 and 2020R1A2C3009667) and the Ministry of Health and Welfare of Korea (Grant No. HI15C0001). Code, Data, and Materials AvailabilityThe data that support the findings of this study are available from the corresponding author, WYO, upon reasonable request. ReferencesH. Girouard and C. Iadecola,
“Neurovascular coupling in the normal brain and in hypertension, stroke, and Alzheimer disease,”
J. Appl. Physiol., 100
(1), 328
–335
(2006). https://doi.org/10.1152/japplphysiol.00966.2005 Google Scholar
C. Iadecola,
“Regulation of the cerebral microcirculation during neural activity: is nitric-oxide the missing link,”
Trends Neurosci., 16
(6), 206
–214
(1993). https://doi.org/10.1016/0166-2236(93)90156-G TNSCDR 0166-2236 Google Scholar
C. Iadecola,
“The neurovascular unit coming of age: a journey through neurovascular coupling in health and disease,”
Neuron, 96
(1), 17
–42
(2017). https://doi.org/10.1016/j.neuron.2017.07.030 NERNET 0896-6273 Google Scholar
B. R. Chen et al.,
“A critical role for the vascular endothelium in functional neurovascular coupling in the brain,”
J. Am. Heart Assoc., 3
(3),
(2014). https://doi.org/10.1161/JAHA.114.000787 Google Scholar
T. A. Longden et al.,
“Capillary K+-sensing initiates retrograde hyperpolarization to increase local cerebral blood flow,”
Nat. Neurosci., 20
(5), 717
(2017). https://doi.org/10.1038/nn.4533 NANEFN 1097-6256 Google Scholar
S. Ogawa et al.,
“Intrinsic signal changes accompanying sensory stimulation—functional brain mapping with magnetic-resonance-imaging,”
Proc. Natl. Acad. Sci. U. S. A., 89
(13), 5951
–5955 https://doi.org/10.1073/pnas.89.13.5951 Google Scholar
C. Iadecola et al.,
“Local and propagated vascular responses evoked by focal synaptic activity in cerebellar cortex,”
J. Neurophysiol., 78
(2), 651
–659
(1997). https://doi.org/10.1152/jn.1997.78.2.651 JONEA4 0022-3077 Google Scholar
S. A. Sheth et al.,
“Spatiotemporal evolution of functional hemodynamic changes and their relationship to neuronal activity,”
J. Cereb. Blood Flow Metab., 25
(7), 830
–841
(2005). https://doi.org/10.1038/sj.jcbfm.9600091 Google Scholar
B. R. Chen et al.,
“High-speed vascular dynamics of the hemodynamic response,”
Neuroimage, 54
(2), 1021
–1030
(2011). https://doi.org/10.1016/j.neuroimage.2010.09.036 NEIMEF 1053-8119 Google Scholar
D. Kleinfeld et al.,
“Fluctuations and stimulus-induced changes in blood flow observed in individual capillaries in layers 2 through 4 of rat neocortex,”
Proc. Natl. Acad. Sci. U. S. A., 95
(26), 15741
–15746
(1998). https://doi.org/10.1073/pnas.95.26.15741 Google Scholar
W. Denk, J. H. Strickler and W. W. Webb,
“Two-photon laser scanning fluorescence microscopy,”
Science, 248
(4951), 73
–76
(1990). https://doi.org/10.1126/science.2321027 SCIEAS 0036-8075 Google Scholar
C. Cai et al.,
“Stimulation-induced increases in cerebral blood flow and local capillary vasoconstriction depend on conducted vascular responses,”
Proc. Natl. Acad. Sci. U. S. A., 115
(25), E5796
–E5804
(2018). https://doi.org/10.1073/pnas.1707702115 Google Scholar
R. L. Rungta et al.,
“Vascular compartmentalization of functional hyperemia from the synapse to the pia,”
Neuron, 101
(4), 762
(2019). https://doi.org/10.1016/j.neuron.2019.01.060 NERNET 0896-6273 Google Scholar
A. Y. Shih et al.,
“Two-photon microscopy as a tool to study blood flow and neurovascular coupling in the rodent brain (vol 32, pg 1277, 2013),”
J. Cereb. Blood Flow Metab., 33
(2), 319
–319
(2013). https://doi.org/10.1038/jcbfm.2012.177 Google Scholar
J. Lee et al.,
“Statistical intensity variation analysis for rapid volumetric imaging of capillary network flux,”
Biomed. Opt. Express, 5
(4), 1160
–1172
(2014). https://doi.org/10.1364/BOE.5.001160 BOEICL 2156-7085 Google Scholar
H. Radhakrishnan and V. J. Srinivasan,
“Compartment-resolved imaging of cortical functional hyperemia with OCT angiography,”
Biomed. Opt. Express, 4
(8), 1255
–1268
(2013). https://doi.org/10.1364/BOE.4.001255 BOEICL 2156-7085 Google Scholar
P. Shin et al.,
“Quantitative hemodynamic analysis of cerebral blood flow and neurovascular coupling using optical coherence tomography angiography,”
J. Cereb. Blood Flow Metab., 39
(10), 1983
–1994
(2019). https://doi.org/10.1177/0271678X18773432 Google Scholar
M. W. Reed and F. N. Miller,
“Importance of light dose in fluorescent microscopy,”
Microvasc. Res., 36
(1), 104
–107
(1988). https://doi.org/10.1016/0026-2862(88)90042-8 MIVRA6 0026-2862 Google Scholar
R. K. Saetzler et al.,
“Intravital fluorescence microscopy: impact of light-induced phototoxicity on adhesion of fluorescently labeled leukocytes,”
J. Histochem. Cytochem., 45
(4), 505
–513
(1997). https://doi.org/10.1177/002215549704500403 JHCYAS 0022-1554 Google Scholar
G. J. Goldey et al.,
“Removable cranial windows for long-term imaging in awake mice,”
Nat. Protoc., 9
(11), 2515
–2538
(2014). https://doi.org/10.1038/nprot.2014.165 1754-2189 Google Scholar
E. Moult et al.,
“Ultrahigh-speed swept-source OCT angiography in exudative AMD,”
Ophthal. Surg. Lasers Imaging Retina, 45
(6), 496
–505
(2014). https://doi.org/10.3928/23258160-20141118-03 RETIDX 0275-004X Google Scholar
A. Devor et al.,
“Stimulus-induced changes in blood flow and 2-deoxyglucose uptake dissociate in ipsilateral somatosensory cortex,”
J. Neurosci., 28
(53), 14347
–14357
(2008). https://doi.org/10.1523/JNEUROSCI.4307-08.2008 JNRSDS 0270-6474 Google Scholar
M. A. Franceschini et al.,
“The effect of different anesthetics on neurovascular coupling,”
Neuroimage, 51
(4), 1367
–1377
(2010). https://doi.org/10.1016/j.neuroimage.2010.03.060 NEIMEF 1053-8119 Google Scholar
K. Masamoto and I. Kanno,
“Anesthesia and the quantitative evaluation of neurovascular coupling,”
J. Cereb. Blood Flow Metab., 32
(7), 1233
–1247
(2012). https://doi.org/10.1038/jcbfm.2012.50 Google Scholar
|