1 February 1989 Co2 Waveguide Laser With Programmable Pulse Profile
Dietmar Letalick, Ingmar Renhorn, Anders Widen
Author Affiliations +
Abstract
A CO2 waveguide laser with programmable pulse profile, intended for use in coherent laser radar applications, has been designed and characterized. Gain and intracavity losses were measured and compared with known component losses and theoretical mode coupling efficiencies. A set of coupled rate equations was used for calculating the peak power. Input parameters in those calculations were the measured gain and loss together with published data on population relaxation. The observed Q-switched pulse was in reasonable agreement with the calculated pulse form. Average power and peak power could be fitted to simple empirical formulas. Q-switched and cavity-dumped pulses with a pulse length of 13 ns were demonstrated, limited only by the pulse generator. The pulse length is ultimately limited by the cavity round-trip time.
Dietmar Letalick, Ingmar Renhorn, and Anders Widen "Co2 Waveguide Laser With Programmable Pulse Profile," Optical Engineering 28(2), 282172 (1 February 1989). https://doi.org/10.1117/12.7976926
Published: 1 February 1989
Lens.org Logo
CITATIONS
Cited by 8 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Carbon dioxide

Carbon dioxide lasers

Waveguide lasers

Q switching

LIDAR

Pulse generators

RELATED CONTENT

New advances in 2 ?m high power dual frequency single...
Proceedings of SPIE (November 17 2017)
CO2 Laser Radar Transmitters
Proceedings of SPIE (March 31 1983)
Research on TEA 13C16O2 laser for LDIAL
Proceedings of SPIE (May 31 2006)
First open field measurements with a portable CO2 lidar dial...
Proceedings of SPIE (September 30 2011)
CO2 laser setup for long-range DIAL lidar
Proceedings of SPIE (January 25 2000)

Back to Top