We present the design and performance of the XRISM Soft X-Ray Spectrometer Resolve, successfully launched on a JAXA H-IIA rocket September 7, 2023. The instrument uses a 36-pixel array of microcalorimeters at the focus of a grazing-incidence x-ray mirror. The instrument has achieved an energy resolution of 4.5 eV (FWHM) at 6. The overall cooling chain was designed to provide a lifetime of at least 3 years in orbit and operate without liquid helium to provide redundancy and the longest operational lifetime for the instrument. Early indications that the cryogen lifetime will exceed 4 years. X-rays are focused onto the array with a high-throughput grazing incidence X-ray Mirror Assembly with over 200 nested two-stage X-ray reflectors. A series of onboard X-ray calibrations sources allow simultaneous energy scale calibration lines simultaneously while observing celestial sources. The inflight performance of Resolve will be described along with a summary of the scientific capabilities.
The initial on-orbit checkout of the soft X-ray spectroscopic system on board the XRISM satellite is summarized. The satellite was launched on September 6, 2023 (UT) and has been undergoing initial checkout since then. Immediately after the launch, the cryocoolers were turned on and their operation was established. The first cycle of the adiabatic demagnetization refrigerator was performed on Oct. 9th, 2023, to transition the sensor to steady-state operational temperature conditions. Subsequently, the filter wheel, which supports energy calibration, was started up. The energy scale is highly sensitive to the temperature environment around the sensor and its analog electronics. The gain correction was established by referring to the calibration X-ray line. For an optimization of the cooler frequencies, we took data including the noise spectra by scanning the cooler frequencies, and selected a good frequency pair in the on-orbit environment. At the last stage of the checkout, the gate valve, which protects the inside of the Dewar from outside air pressure at launch, was attempted to be opened to bring the system to a state where it is ready for regular operations but was failed.
The X-Ray Imaging and Spectroscopy Mission (XRISM) project at JAXA officially started in 2018. Following the development of onboard components, the proto-flight test was conducted from 2021 to 2023 at JAXA Tsukuba Space Center. The spacecraft was launched from JAXA Tanegashima Space Center on September 7, 2023 (JST), and onboard components, including the science instruments, were activated during the in-orbit commissioning phase. Following the previous report in 2020, we report the spacecraft ground tests, the launch operation, in-orbit operations, and the status and plan of initial and subsequent guest observations.
Resolve is the instrument that utilizes an X-ray micro-calorimeter array onboard the XRISM (X-Ray Imaging and Spectroscopy Mission), which was launched on September 6 (UT), 2023. It fully met the spectral performance requirement (7 eV at 6 keV) both on the ground and in orbit and was confirmed to have the same performance as the SXS onboard the ASTRO-H (Hitomi) satellite. The detectors are operated at a low temperature of 50 mK to achieve the required energy resolution with the cooling system to satisfy the lifetime requirement of over 3 years. The cooling system is equipped with a 3-stage ADR and superfluid liquid He (LHe) as the heat sink for the ADR. The Joule-Thomson cooler unit and 2-stage Stirling cooler units are adopted to reduce heat load to the LHe. In the pre-launch operations, we carried out the low-temperature LHe top-off operation. The resultant amount of liquid He was over 35 L at the launch, which is sufficient to meet the lifetime requirement. During the post-launch operation, the LHe vent valve was opened five minutes after launch during the rocket acceleration, and the cryocoolers started in several revolutions as planned which established stable cooling of the dewar.
KEYWORDS: Magnetism, Electromagnetic coupling, Space operations, X-rays, Antennas, X band, Electromagnetic interference, Equipment, Device simulation, S band
Electromagnetic interference (EMI) for low-temperature detectors is a serious concern in many missions. We investigate the EMI caused by the spacecraft components to the x-ray microcalorimeter of the Resolve instrument onboard the x-ray imaging and spectroscopy mission, which is currently under development by an international collaboration and is planned to be launched in 2023. We focus on the EMI from (a) the low-frequency magnetic field generated by the magnetic torquers (MTQ) used for the spacecraft attitude control and (b) the radio-frequency (RF) electromagnetic field generated by the S and X band antennas used for communication between the spacecraft and the ground stations. We executed a series of ground tests both at the instrument and spacecraft levels using the flight-model hardware in 2021–2022 in a JAXA facility in Tsukuba. We also conducted electromagnetic simulations partially using the Fugaku high-performance computing facility. The MTQs were found to couple with the microcalorimeter, which we speculate through pick-ups of low-frequency magnetic field and further capacitive coupling. There is no evidence that the resultant energy resolution degradation is beyond the current allocation of noise budget. The RF communication system was found to leave no significant effect. We present the result of the tests and simulation in this article.
Electromagnetic interference (EMI) for low-temperature detectors is a serious concern in many missions. We investigate the EMI caused by the spacecraft components to the x-ray microcalorimeter of the Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), which is currently under development by an international collaboration and is planned to be launched in 2023. We focus on the EMI from (a) the low-frequency magnetic field generated by the magnetic torquers used for the spacecraft attitude control and (b) the radio-frequency (RF) electromagnetic field generated by the s and x band antennas used for communication between the spacecraft and the ground stations. We executed a series of ground tests both at the instrument and spacecraft levels using the flight model hardware in 2021–2022 in a JAXA facility in Tsukuba. We also conducted electromagnetic simulations partially using the Fugaku high-performance computing facility. The magnetic torquers were found to couple with the microcalorimeter, but there is no evidence that the resultant degradation is beyond the current allocation of noise budget. The RF communication system was found to leave no significant effect. We present the result of the tests and simulation in this article.
The X-Ray Imaging and Spectroscopy Mission (XRISM) is the successor to the 2016 Hitomi mission that ended prematurely. Like Hitomi, the primary science goals are to examine astrophysical problems with precise highresolution X-ray spectroscopy. XRISM promises to discover new horizons in X-ray astronomy. XRISM carries a 6 x 6 pixelized X-ray micro-calorimeter on the focal plane of an X-ray mirror assembly and a co-aligned X-ray CCD camera that covers the same energy band over a large field of view. XRISM utilizes Hitomi heritage, but all designs were reviewed. The attitude and orbit control system were improved in hardware and software. The number of star sensors were increased from two to three to improve coverage and robustness in onboard attitude determination and to obtain a wider field of view sun sensor. The fault detection, isolation, and reconfiguration (FDIR) system was carefully examined and reconfigured. Together with a planned increase of ground support stations, the survivability of the spacecraft is significantly improved.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.