Imaging and measurement of drops-in-flight often relies on the measurement system's ability to drive the print head
directly in order to synchronize the strobe for repeatable image capture. In addition, many systems do not have the
necessary combination of strobe control and image analysis for full drop-in-flight evaluation.
This paper includes a discussion of an integrated machine-vision based system for visualization and measurement of
drops-in-flight that can be used with any frequency-based jetting system. The strobe is linked to the firing frequency of
the print head, so while it is synchronized, it is independent of the specific print head being inspected.
The imaging system resolves droplets down to 2 picoliters in volume at the highest zoom level. And an open architecture
software package allows for image collection and archiving as well as powerful and flexible image analysis.
This paper will give an overview of the details of this system as well as show some of the system capabilities through
several examples of drop-in-flight analysis.
Inspection of electrophotographic print cartridge quality and compatibility requires analysis of hundreds of pages on a wide population of printers and copiers. Although print quality inspection is often achieved through the use of anchor prints and densitometry, more comprehensive analysis and quantitative data is desired for performance tracking, benchmarking and failure mode analysis. Image quality measurement systems range in price and performance, image capture paths and levels of automation. In order to address the requirements of a specific application, careful consideration was made to print volume, budgetary limits, and the scope of the desired image quality measurements. A flatbed scanner-based image quality measurement system was selected to support high throughput, maximal automation, and sufficient flexibility for both measurement methods and image sampling rates. Using an automatic document feeder (ADF) for sample management, a half ream of prints can be measured automatically without operator intervention. The system includes optical character recognition (OCR) for automatic determination of target type for measurement suite selection. This capability also enables measurement of mixed stacks of targets since each sample is identified prior to measurement. In addition, OCR is used to read toner ID, machine ID, print count, and other pertinent information regarding the printing conditions and environment. This data is saved to a data file along with the measurement results for complete test documentation. Measurement methods were developed to replace current methods of visual inspection and densitometry. The features that were being analyzed visually could be addressed via standard measurement algorithms. Measurement of density proved to be less simple since the scanner is not a densitometer and anything short of an excellent estimation would be meaningless. In order to address the measurement of density, a transfer curve was built to translate the gray scale values that are the fundamental scanner output into an estimation of density. The correlation coefficient was excellent and was deemed to be adequate for this application.
This paper addresses the automation process, image analysis and data management required by this application.
This paper describes the status of the INCITS W1.1 macro-uniformity ad hoc team, towards development of standards for perceptual image quality for color printers. The team has defined the macro-uniformity attribute, has developed several test patterns to be used for subjective and objective evaluations and has defined test patterns and methods to address color conversions of digitizing devices. A set of print samples, originating from diverse printing systems, has been established, and digitization of these samples is in progress. These activities and next steps are reviewed in this paper.
There are many challenges in inspecting inkjet nozzle plates. For example, orifice sizes have gotten smaller and smaller to support smaller drop sizes. Reflective plate materials create difficulties in capturing high-contrast, top-illuminated imagery. Time constraints in production environments require high-speed image capture, feature inspection and part disposition. Current systems use 2D CCD array cameras to step and repeat inspection along the length of each plate. Step and repeat methods have inherent limitations in inspection time, focus and illumination. In response to customer needs for a more robust methodology, a line-scan camera based inspection system has been developed. This paper will describe the line-scan based inspection system including considerations for image improvement through both hardware and software modifications. System capabilities and limitations will be discussed.
Color hardcopy output is subject to many of the same image quality concerns as monochrome hardcopy output. Line and dot quality, uniformity, halftone quality, the presence of bands, spots or deletions are just a few by both color and monochrome output. Although measurement of color requires the use of specialized instrumentation, the techniques used to assess color-dependent image quality attributes on color hardcopy output are based on many of the same techniques as those used in monochrome image quality quantification. In this paper we will be presenting several different aspects of color quality assessment in both R and D and production environments. As well as present several examples of color quality measurements that are similar to those currently being used at Hewlett-Packard to characterize color devices and to verify system performance. We will then discuss some important considerations for choosing appropriate color quality measurement equipment for use in either R and D or production environments. Finally, we will discuss the critical relationship between objective measurements and human perception.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please