Our previous development was to bent Si crystals to the cylindrical shape of circle and parabola with the DLC deposition. However, for the better optics for the X-ray polarimetry, the shape should be the paraboloid of revolution to collect X-rays with high S/N ratio. We searched for the method to bent the Si crystals to the shape of the paraboloid of revolution. We devised the method to mold the crystal and the CFRP substrate simultaneously pushed to the sophisticated foundation with the paraboloid of revolution. We developed the prototype of about 8 inch in radius of one-quater size. The crystals was also bent in the circumferential direction. Therefore, the image capability examined with optical parallel beam is 0.6 degree. In this thesis, we discussed the new design for X-ray spectroscopic polarimetry, the evaluation of image capability.
ASTRO-H is equipped with two modules of the SXT; one is for the Soft X-ray Spectrometer (SXS), an X-ray calorimeter, and the other is for the Soft X-ray Imager (SXI), an X-ray CCD camera. These SXT modules are called SXT-S and SXT-I, respectively. Of the two detector systems, the SXI has a large field of view, a square with 38' on a side. To cope with this, we have made a mosaic mapping of the stray light at a representative off-axis angle of 30' in the X-ray beam line at the Institute of Space and Astronautical Science. The effective area of the brightest secondary reflection is found of order 0.1% of the on-axis effective area at the energy of 1.49 keV. The other components are not so bright (<5 X 10-4 times smaller than the on-axis effective area). On the other hand, we have found that the effective area of the stray light in the SXS field of view (~3'x3') at large off-axis angles (>15') are ~10-4 times smaller than the on-axis effective area (~590 cm2 at 1.49 keV).
We present the current status of the calibration activity of two SXTs (SXT-1 and SXT-2). The developments of two SXTs were completed by NASA's Goddard Space Flight Center (GSFC). First X-ray measurements with a diverging beam at the GSFC 100m beamline found an angular resolution at 8.0 keV to be 1.1 and 1.0 arcmin (HPD) for SXT-1 and SXT-2, respectively. The full characterization of the X-ray performance has been now continuously calibrated with the 30m X-ray beamline facility at the Institute of Space and Astronautical Science (ISAS) of Japan Aerospace eXploration Agency (JAXA) in Japan. We adopted a raster scan method with a narrow X-ray pencil beam with the divergence of ~ 15". X-ray characterization of the two SXTs has been measured from May and December 2013, respectively.
In the case of SXT-1, the on-axis effective area was approximately 580, 445, 370, 270, 185 and 90 cm2 at energies of 1.5, 4.5, 8.0, 9.4, 11.1 and 12.9 keV respectively. The effective area of SXT-2 is 2% larger than that of SXT-1 irrespective to X-ray energy. The on-axis angular resolution of SXT-1 was evaluated as 1.3 - 1.5 arcmin (HPD) in the 1.5 - 13 keV band. The resolution was slightly got worse at higher energies by ~ 0:3 arcmin. Otherwise, the resolution of SXT-2 is 1.2 arcmin, almost irrespective to X-ray energy. The field of view (FOV) was ~ 16 arcmin at 1.5 keV, decreasing with increasing X-ray energy, and became ~ 8 arcmin at 13 keV. The FOV is defined here as the full-width at half-maximum (FWHM) of the vignetting curve.
The X-ray performance of SXT-1 and SXT-2 meets the system requirements. Because all the parameters of the SXT-2 is slightly better that of SXT-1, we adopted the SXT-2 telescope for the SXS detector of the Astro-H primary instrument with the narrow FOV.
ASTRO-H is an international X-ray mission of ISAS/JAXA, which will be launched in 2014. One of the main characteristics of ASTRO-H is imaging spectroscopy in the hard X-ray band above 10 keV. ASTRO-H will carry two identical Hard X-ray telescopes (HXTs), whose mirror surfaces are coated with Pt/C depth-graded multilayers to enhance hard X-ray effective area up to 80 keV.
HXT was designed based on the telescope on board the SUMIT balloon borne experiment. After feasibility study of the HXT design, the FM design has been deteremined. Mass production of the mirror shells at Nagoya University has been going on since August 2010, and production of mirror shells for HXT-1 was completed in March 2012. After the integation of X-ray mirrors for HXT-1, we measured hard X-ray performance of selected mirror shells for HXT-1 at a synchrotron radiation facility, SPring-8 beamline BL20B2. We will perform environment tests and ground calibarations at SPring-8 for HXT-1. In HXT-2, foil production is going on.
View contact details