We propose a method to generate accurate proton relative stopping power (RSP) maps from patient cone-beam CT (CBCT) images. The scatter polluted low frequency component in the CBCT projections is replaced by an analytically calculated estimate of the scatter-free component. This is obtained by forward projecting the segmented CBCT image overridden with reference materials (air, soft tissue, bone). The projection model accounts for polychromaticity and uses an estimate of the combined source-detector spectral function. High and low frequency image components are automatically matched. The accurate conversion curve from CT numbers to RSP is obtained by comparison of a proton radiography and a proton digitally reconstructed radiography. CBCT images are acquired on a clinical scanner and proton images are simulated by Monte Carlo. Results show clearly reduced cupping effect and overall better RSP accuracy when CBCT images are scatter corrected.
KEYWORDS: Computed tomography, Signal to noise ratio, Gated imaging, Motion models, Radiotherapy, Tumors, Signal processing, CT reconstruction, Scanners, Medical imaging
In radiotherapy, the respiratory motion of the patient in treatment position is determined from gated cone-beam CT images. This method consists in selecting projections according to a respiratory signal for the reconstruction of a CT image of each respiratory state. This selection can be based on the amplitude or the phase of the signal. The number of selected projections also depends on the width of the gating window. The present study compares different reconstructions using a dynamic digital phantom of the thorax and a known respiratory signal. We applied both regular and irregular motions to this phantom and reconstructed the exhale state using different widths. We evaluated these reconstructions with the signal-to-noise ratio, the contrast-to-noise ratio and a blur criterion. In the case of a regular motion, there was no difference between the amplitude and the phase. The signal quality was high, even for the smallest width, and the blur increased with width. In the case of an irregular motion, the difference was noticeable. Amplitude-based reconstructions suffered from severe artifacts with the smallest width because there were respiratory cycles for which no projection was selected. This drawback is overcome by increasing the width of the gating window. Phase-based reconstructions also allowed to avoid artifacts, whatever the width. But the blur was higher, even for the smallest width applied. These results suggest that the gating process must be adjusted in order to select at least one projection per respiratory cycle. Phase gating is a robust way to achieve this goal when respiration is irregular. Amplitude gating may be more effective in terms of blur, but the width must be carefully chosen to avoid severe artifacts. Finally, we observed the potential of dynamic reconstruction by using a motion model to deform different gated CT images toward a common reference and compute the weighted mean. The resulting CT image suffered less from artifacts than each gated CT image separately even if artifacts were still visible.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.