The modern needs of the electro optical market for small low-power and light-weight IR systems are impelling development of High Operating Temperature (HOT) IR detectors, requiring development of dedicated cryocoolers. The development of cryocoolers focused on “SWAP-C” configuration means small size, low weight, low power consumption and attractive cost, in order to optimize IDDCA for modern compact thermal imagers. This paper will review the progress made with the new rotary K580 cryocooler for HOT detectors, update on qualification and life demonstration test results, present test results accumulated from production ramp-up and review the compliance with advanced HOT format arrays. The paper will also review planning for advanced Rotary version as further step of excellence with "SWAP-C" parameters.
The growing demand for EO applications that work around the clock 24hr/7days a week, such as in border surveillance systems, emphasizes the need for a highly reliable cryocooler having increased operational availability and optimized system's Integrated Logistic Support (ILS). In order to meet this need, RICOR developed linear and rotary cryocoolers which achieved successfully this goal. Cryocoolers MTTF was analyzed by theoretical reliability evaluation methods, demonstrated by normal and accelerated life tests at Cryocooler level and finally verified by field data analysis derived from Cryocoolers operating at system level. The following paper reviews theoretical reliability analysis methods together with analyzing reliability test results derived from standard and accelerated life demonstration tests performed at Ricor's advanced reliability laboratory. As a summary for the work process, reliability verification data will be presented as a feedback from fielded systems.
The modern needs of the electro-optical market for small low-power and light-weight IR systems are impelling research and development of High Operating Temperature (HOT) IR detectors, requiring development of dedicated “HOT” cryocoolers. The development of cryocoolers with emphasis on the “SWAP3” configuration means small size, low weight, improved performance, low power consumption and low price, in order to optimize IDDCA for future hand held thermal sights. This paper will present the development and the progress made with the new "HOT" cryocooler, including customer data after the evaluation process, performances achieved using a common cold finger, test results update on a large series of production coolers, life and qualification test update and acoustic noise reduction. All the above mentioned information relates to the FPA temperature range of 130 - 200K for various cryocooler models based on rotary and linear design concepts. The paper will also review the progress with the latest development activities implemented in the cryocoolers and the electronic control modules in order to improve reliability and minimize regulated power consumption.
Ricor cryogenics was founded in 1967 and since then it has focused on innovative technologies in the cryogenic field. The paper reviews the initial research and development efforts invested in various technologies that have yielded products such as Cryostats for Mossbauer Effect measurement, Liquid gas Dewar containers, Liquid helium vacuum transfer tubes, Cryosurgery and other innovative products. The major registered patents that matured to products such as a magnetic vacuum valve operator, pumped out safety valve and other innovations are reviewed here. As a result of continuous R and D investment, over the years a new generation of innovative Stirling cryogenic products has developed. This development began with massive split slip-on coolers and has progressed as far as miniature IDDCA coolers mainly for IR applications. The accumulated experience in Stirling technology is used also as a platform for developing self-contained water vapor pumps known as MicroStar and NanoStar. These products are also used in collaboration with a research institute in the field of High Temperature Superconductors. The continuous growth in the cryogenic products range and the need to meet market demands have motivated the expansion, of Ricor's manufacturing facility enabling it to become a world leader in the cryocooler field. To date Ricor has manufactured more than 120,000 cryocoolers. The actual cryogenic development efforts and challenges are also reviewed, mainly in the field of long life cryocoolers, ruggedized products, miniaturization and products for space applications.
KEYWORDS: Cryocoolers, Reliability, Cryogenics, Sensors, Accelerated life testing, Systems modeling, Interfaces, 3D modeling, Chemical analysis, Algorithm development
Early rotary cryocoolers were designed for the lifetime of a few thousands operating hours. Ricor K506 model’s life
expectancy was only 5,000 hours, then the next generation K508 model was designed to achieve 10,000 operating hours
in basic conditions, while the modern K508N was designed for 20,000 operating hours.
Nowadays, the new challenges in the field of rotary cryocoolers require development of a new generation cooler that
could compete with the linear cryocooler reliability, achieving the lifetime goal of 30,000 operating hours, and even
more.
Such new advanced cryocooler can be used for upgrade existing systems, or to serve the new generation of high-temperature
detectors that are currently under development, enabling the cryocooler to work more efficiently in the field.
The improvement of the rotary cryocooler reliability is based on a deep analysis and understating of the root failure
causes, finding solutions to reduce bearings wear, using modern materials and lubricants. All of those were taken into
consideration during the development of the new generation rotary coolers.
As a part of reliability challenges, new digital controller was also developed, which allows new options, such as discrete
control of the operating frequency, and can extend the cooler operating hours due to new controlling technique. In
addition, the digital controller will be able to collect data during cryocooler operation, aiming end of life prediction.
The world growth in research and development of High Operating Temperature (HOT) IR detectors impels the
development and optimization of suitable cryocoolers. The current developments at RICOR, which include three
different cryocooler models and two new controllers, are focused on the - oriented design process, meaning small
Size, low Weight, low Power consumption, improved performance and lower production cost, providing proper
cryocoolers for future hand held thermal imagers.
This paper shows the progress made during development of “HOT” cryocooler prototypes, engineering pre-production
series and qualified production series cryocoolers working at the FPA temperature range of 130 - 200K. The progress
with development of electronic control modules providing minimized regulated power consumption is also shown.
The progress in development of cryocoolers reliability is also reported in the paper.
KEYWORDS: Cryogenics, Space operations, Sensors, Aerospace engineering, Mars, Temperature metrology, Fermium, Frequency modulation, Climatology, Helium
Cryogenic refrigerators represent a significant enabling technology for Earth and Space science enterprises. Many of the space instruments require cryogenic refrigeration to enable the use of advanced detectors to explore a wide range of phenomena from space. RICOR refrigerators involved in various space missions are overviewed in this paper, starting in 1994 with “Clementine” Moon mission, till the latest ExoMars mission launched in 2016. RICOR tactical rotary refrigerators have been incorporated in many space instruments, after passing qualification, life time, thermal management testing and flight acceptance. The tactical to space customization framework includes an extensive characterization and qualification test program to validate reliability, the design of thermal interfacing with a detector, vibration export control, efficient heat dissipation in a vacuum environment, robustness, mounting design, compliance with outgassing requirements and strict performance screening. Current RICOR development is focused on dedicated ultra-long-life, highly reliable, space cryogenic refrigerator based on a Pulse Tube design
The growth in world demand for infrared missile warning systems (MWS) has impelled the development of new technologies, in particular, special ruggedized cryogenic coolers. Since the cryocooler is a core component in ruggedized platforms, RICOR has met the challenge by developing new models able to withstand high ambient temperatures above 110°C, as well as harsh vibration levels, both derived from airborne fighter applications. One of the development efforts focused on a cryocooler regenerator and cold finger optimization, in order to achieve high cooling capacity at 95K FPA and the efficiency of about 5.3 % at 102 °C.
In order to withstand harsh environmental vibration and high ambient temperature range, the mechanical parts of the cryocoolers were designed and tested for a high structural safety factor along with weight minimization. The electronic design concept was based on encapsulated controllers, the PCB of which has been designed with internal heat sinking paths and special components able to withstand ambient temperatures of up to 125°C.
As a final stage of development, four cryocooler models (K544, K549, K527 and K508) were successfully qualified under harsh environmental conditions, both by RICOR and by system manufacturers. Also life demonstration tests were performed with these models. The cryocoolers were designed and tested successfully to meet requirements of military standards MIL- STD-704D, MIL-STD- 461E and MIL-STD-810F reflecting real mission profiles in harsh environment.
The world growth in research and development of High Operating Temperature (HOT) IR detectors impels development and optimization of suitable cryocoolers. The current developments at RICOR are focused on the SWAP-oriented design process, meaning small Size, low Weight and low Power consumption, providing proper cryocoolers for future hand held thermal imagers.
This paper shows the progress made during development of "HOT" cryocooler prototypes, and engineering preproduction series cryocoolers working at the FPA temperature range of 130 - 200K. Three different cryocooler models based on rotary & linear design concepts are presented below. The progress with development of electronic control modules providing minimized regulated power consumption is also shown.
The growing demand for Electro Optic (EO) applications that work around the clock 24hr/7days a week, such as in border surveillance systems, emphasizes the need for a highly reliable Cryocooler having increased operational availability and decreased integrated system Life Cycle (ILS) cost. In order to meet this need, RICOR has developed Integral Rotary and Split Linear Cryocoolers technologies which meet this challenge. RICOR’s Cryocoolers reliability characteristics are assessed by analytical reliability models, demonstrated by normal and accelerated life tests and finally verified by field data. The paper will focus on the reliability evaluation models for different technologies, report and analyze life demonstration test data at different mission profiles and verify the results by fielded Cryocoolers operating as a feedback to approve the theoretical assumptions and calculation models. In addition, it will review the system's end user needs and expectations from advanced high reliable Cryocoolers.
The world growth in research and development of High Operating Temperature IR detectors impels the development process and the optimization of HOT Cryocoolers at RICOR. The development emphasizes the “SWaP” configuration which is Small Size, Low Weight and Low Power consumption, in order to optimize IDDCA for future hand held thermal sights and other various applications. This paper will present optimization tests results performed on HOT Lab Demonstration Cryocoolers at the temperature range of 130 - 180K FPA and also will review the development activities that will be implemented in order to minimize "Idle electronic and mechanical losses", hence minimizing the regulated power consumption. The new Cryocoolers developed for HOT detectors aim for higher reliability which is analyzed and reported in the paper.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.