The Silicon Pore Optics (SPO) enables the NewAthena mission, delivering an unprecedented combination of good angular resolution, large effective area and low mass. The SPO technology builds significantly on spin-in from the semiconductor industry and is designed to allow a cost-effective flight optics implementation, compliant with the programmatic requirements of the mission.
The NewAthena X-ray optics is highly modular, consisting of hundreds of compact mirror modules arranged in concentric circles and mounted on a metallic optical bench. All aspects of the optics are being developed in parallel, from the industrial production of the mirror plates, over the highly efficient assembly into mirror modules, to the alignment of the mirror modules and their fixation on the optical bench. Dedicated facilities are being built to measure the performance of the NewAthena X-ray telescope optics, demonstrating their compatibility with the environmental and scientific requirements.
An overview is provided of the activities preparing the implementation of the NewATHENA optics.
The Einstein Probe (EP) is a mission of the Chinese Academy of Sciences (CAS) dedicated to time-domain high-energy astrophysics. Its primary goals are to discover high-energy transients and monitor variable objects. The ESA Science Programme Committee (SPC) approved on 19 June 2018 the participation of ESA to the CAS EP mission as a mission of opportunity. Among other elements, CAS has requested ESA participation for the provision of the mirror modules of the follow-up x-ray telescope (FXT).
FXT is a pair of Wolter-I telescopes operating in the 0.5-10 keV energy range, inheriting the design from eROSITA [2][3]. It provides field of view of about 1 deg diameter. The source localization error will be of 5-15 arcsec depending on the source strength [1]. The FXT is responsible for the quick follow-up observations of the triggered sources and will also observe other interested targets during the all-sky survey at the rest time.
Three FXT mirror modules were produced: structural and thermal model (STM), qualification model (QM) and flight model (FM). Media Lario could leverage on the manufacturing and integration infrastructure still available at its premises from the eROSITA programme [3][4], including the complete set of 54 mandrels needed for the mirror repliforming, property of MPE.
Media Lario produced and integrated the FXT mirror modules, each comprising 54 nested repliformed mirror shells; Max-Planck Institute (MPE) conducted the x-ray optical tests at the PANTER facility, for the acceptance of all the different models. This efficient collaboration enabled the on-time and in-quality delivery of the FXT mirror modules.The next generation x-ray observatory ATHENA (advanced telescope for high energy astrophysics) requires an optics with unprecedented performance. It is the combination of low mass, large effective area and good angular resolution that is the challenge of the x-ray optics of such a mission. ATHENA is the second large class mission in the science programme of ESA, and is currently in a reformulation process, following a design-to-cost approach to meet the cost limit of an ESA L-class mission.
The silicon pore optics (SPO) is the mission enabler being specifically developed for ATHENA, in a joint effort by industry, research institutions and ESA. All aspects of the optics are being addressed, from the mirror plates and their coatings, over the mirror modules and their assembly into the ATHENA telescope, to the facilities required to build and test the flight optics, demonstrating performance, robustness, and programmatic compliance.
The SPO technology is currently being matured to the level required for the adoption of the ATHENA mission, i.e., the start of the mission implementation phase. The monocrystalline silicon material and pore structure of the SPO provide these optics with excellent thermal and mechanical properties. Benefiting from technology spin-in from the semiconductor industry, the equipment, processes, and materials used to produce the SPO are highly sophisticated and optimised.Media Lario used their in-house coordinate measuring machine to adjust the surface during assembly, with the reflector panels facing upwards. As part of the Final Acceptance Review measurements of the surface were undertaken by LMT staff at the Media Lario factory, using both a laser tracker and photogrammetry. Measurements were also made of the electroforming mold for the central panel. The reflector was mounted on a rotating stand allowing surface measurements to be performed according to the respective gravitational load cases. Measurements at the Media Lario factory provided a useful reference for repeat data taken at the LMT site, since the reflector was shipped as a fully assembled unit, designed to require no further adjustment after leaving the factory.
In this paper we present the surface measurements conducted during the review, and comparisons of the observed gravitational load deformations with those predicted by FEA. Although the latter were often at the level of measurement uncertainty, we were able to verify specific cases, as well as performing a sanity check on the manufacturer's design analysis. The measurements confirmed final surface error values leading to reflector acceptance by the project. An RMS surface error of the order of 25 microns over the entire reflector was recorded at 60 degrees elevation using photogrammetry data after adjusting to the best-fit parabola, showing compliance with the LMT specification. Acceptance review measurements also provided a baseline for surface measurements at site prior to installation.
The X-ray telescope of eROSITA will consist of 7 identical and co-aligned mirror modules, each with 54 nested Wolter-1 mirror shells. The mirror shells are glued onto a spider wheel which is screwed to the mirror interface structure making a rigid mechanical unit. The assembly of 7 modules forms a compact hexagonal configuration with 1300 mm diameter (see Fig. 1) and will be attached to the telescope structure which connects to the 7 separate CCD cameras in the focal planes. The co-alignment of the mirror module enables eROSITA to perform also pointed observations.
The replication process described in chapter III allows the manufacturing in one single piece and at the same time of both the parabola and hyperbola parts of the Wolter 1 mirror.
The X-ray telescope of eROSITA will consist of 7 identical and co-aligned mirror modules, each with 54 nested Wolter-1 mirror shells. The mirror shells are glued onto a spider wheel which is screwed to the mirror interface structure making a rigid mechanical unit. The assembly of 7 modules forms a compact hexagonal configuration with 1300 mm diameter (see Fig. 1) and will be attached to the telescope structure which connects to the 7 separate CCD cameras in the focal planes. The co-alignment of the mirror module enables eROSITA to perform also pointed observations.
The replication process described in chapter III allows the manufacturing in one single piece and at the same time of both the parabola and hyperbola parts of the Wolter 1 mirror.
We present first results of demonstrating Silicon Pore Optics for the extreme radial positions of the Athena telescope. For the inner most radii (0.25 m) a new mirror plate design is shown which overcomes the challenges of larger curvatures, higher stress values and bigger plates. Preliminary designs for the mounting system and its mechanical properties are discussed for mirror modules covering all other radial positions up to the most outer radius of the Athena telescope.
View contact details