Abstract
The concentration of free hemoglobin (FHb) in blood bag is an important index to evaluate blood quality. And the chemical method, which is widely used in clinic, not only wastes precious blood resources, but also consumes time, be labor-intensive, and pollutes the environment. Although spectral analysis can make up for the shortcomings of traditional chemical methods, its accuracy also be seriously affected due to unstable the optical parameters of the blood bag and complexity of blood composition. Therefore, this paper proposed a wavelength selection method based on modified ant colony optimization (ACO) algorithm. This algorithm firstly calculates the correlation coefficient between each wavelength and the FHb concentration as the initial pheromone for each wavelength to improve the convergence speed of ACO algorithm; Then, the optimized wavelengths are sorted according to the intensity of the pheromone, the number of optimized wavelengths for modeling is increased in turn, and the root-mean-square error of the model is used as an evaluation index to determine the final optimal wavelength. In this study, a small tube in the front of the blood bag was used as a container, and the transmission spectrum of plasma in the small tube was collected. The regression results of the optimized spectrum were compared with that of the original spectral. The experimental results showed that the method proposed in this paper can obviously improve the analysis accuracy of blood quality, which means this method can effectively inhibit the influence of non-target components and the difference in blood bags on the detection of blood quality.
Conference Presentation
© (2020) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Xingwei Hou, Ling Lin, Gang Li, and Jing Chen "Non-destructive and rapid detection of blood quality in blood bags based on modified ACO wavelength selection algorithm", Proc. SPIE 11231, Design and Quality for Biomedical Technologies XIII, 112310C (17 February 2020); https://doi.org/10.1117/12.2544927
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Blood

Plasma

Data modeling

Optimization (mathematics)

Nondestructive evaluation

Quantitative analysis

Spectroscopy

Back to Top