Poster + Presentation + Paper
15 February 2021 A calibration method for conformal x-ray transmission imaging system
Author Affiliations +
Conference Poster
Abstract
The X-ray source using ZnO nanowires as the cold cathode is first densely integrate a large number of X-ray sources into flat panel devices. Compared with traditional ray sources, X-ray sources device based on ZnO nanowires have small size, instantaneous response, and can be electronically controlled. We propose a new conformal transmission imaging system that uses this flat-panel ray source to irradiate objects with multiple points to complete extremely low-dose projection. In order to get the final image, it is necessary to process the original projection with an image restoration method to remove the projection aliasing caused by multiple point sources. Due to the addition of iteration in the image restoration process, the error caused by the geometric parameters will gradually become larger as the iteration progresses, resulting in distortion of the final image. Therefore, geometric correction of the imaging system is required. The new imaging system has a unique geometric relationship. Based on this geometric relationship, this paper proposes a geometric correction method applied to the new imaging scheme. In this method, the angle parameters in the new imaging system are estimated using a single point volume model. It only needs one projection of the phantom, and it can derive the analytical formula about the three angle errors, which can avoid falling into a local minimum. In this paper, we give the simulation results of the calibration method, which proves the validity and accuracy of the method.
Conference Presentation
© (2021) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yang Li and Xuanqin Mou "A calibration method for conformal x-ray transmission imaging system", Proc. SPIE 11595, Medical Imaging 2021: Physics of Medical Imaging, 115952K (15 February 2021); https://doi.org/10.1117/12.2582284
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Imaging systems

Calibration

Image processing

X-ray imaging

X-rays

X-ray sources

Image restoration

RELATED CONTENT

A high order prior for overlapped projections in the real...
Proceedings of SPIE (September 09 2021)
Planning in-flight calibration for XRISM
Proceedings of SPIE (December 13 2020)
Spatial correlation of some computed images
Proceedings of SPIE (June 10 1993)
Real Time Distortion Correction Of Digital X Ray II TV...
Proceedings of SPIE (March 02 1989)
Geometrical calibration for 3D x-ray imaging
Proceedings of SPIE (June 30 1993)

Back to Top