17 November 2000 Analysis of error in measuring laryngeal size parameters from compressed imagery
Christine Sapienza, Yaser Al-Natour, Mark S. Schmalz, Gerhard X. Ritter
Author Affiliations +
Abstract
The accurate, consistent measurement of laryngeal size parameters is key to the quantification of phonatory disorders from laryngeal endoscopic imagery. Unfortunately, laryngoscopic images contain a wide variety of distortions introduced by endoscope optics (e.g., barrel distortion), systematic effects such as mucus strands adhering to the endoscope lens, electronic noise in the camera or digitization hardware, and color distortions resulting from optical, camera, or digitization errors. These difficulties are compounded by representational errors introduced during image archival or telemedicine-based manipulation of endoscopic imagery, e.g., when images are compressed, stored, then decompressed using lossy transformations. A variety of researchers, in particular Omeori et al., have studied the measurement of laryngeal parameters forma variety of image sources. Unfortunately, such analyses do not account for the effects of image compression/decompression. In this paper, previous research is extended to include estimation of errors in the measurement of parameters such as glottal gap area and maximum vocal fold length from compressed laryngoscopic imagery. Compression transforms studied include JPEG and EBLAST, a relatively recent development in high-compression image transformation for communication along low-bandwidth channels. Error analysis emphasizes preservation of spatial and greylevel information in the decompressed imagery, as well as error in parameter measurement at various compression ratios. Manual as well as automatic methods of laryngeal parameter extraction are analyzed, including techniques based on spectral restriction applied to moderate-resolution RGB imagery (320x200 pixels). The analysis presented herein represents work-in-progress, and is not intended to represent a final implementation suitable for medical diagnostic or life-critical applications, but is advanced as a phenomenological overview of measurement error in the presence of image compression in a medical imaging application.
© (2000) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Christine Sapienza, Yaser Al-Natour, Mark S. Schmalz, and Gerhard X. Ritter "Analysis of error in measuring laryngeal size parameters from compressed imagery", Proc. SPIE 4122, Mathematics and Applications of Data/Image Coding, Compression, and Encryption III, (17 November 2000); https://doi.org/10.1117/12.409240
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image compression

Endoscopes

Chromium

Endoscopy

Error analysis

Transform theory

Tissues

Back to Top