Paper
15 November 2007 Error analysis on laser measurement device of airborne LIDAR
Jianwei Wu, Hongchao Ma
Author Affiliations +
Proceedings Volume 6786, MIPPR 2007: Automatic Target Recognition and Image Analysis; and Multispectral Image Acquisition; 678653 (2007) https://doi.org/10.1117/12.750320
Event: International Symposium on Multispectral Image Processing and Pattern Recognition, 2007, Wuhan, China
Abstract
The error sources of airborne laser measurement device which mainly include laser beam misalignment with respect to scanning mirror, clock error, scanner error and scanner torsion are discussed, and their effects to airborne LIDAR(Light Detection and Ranging)position accuracy are analyzed. Specially, laser beam misalignment's influences to LIDAR scanning line distortion and positioning accuracy are analyzed in detail quantitatively and qualitatively for oscillating scanner. The analysis demonstrates that laser beam misalignment influences the scanning line distortion and positioning accuracy more and more with the increasing height and scanning angle and can't be eliminated by common calibration methods but by the calibration method in factory for it is related to other error sources.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jianwei Wu and Hongchao Ma "Error analysis on laser measurement device of airborne LIDAR", Proc. SPIE 6786, MIPPR 2007: Automatic Target Recognition and Image Analysis; and Multispectral Image Acquisition, 678653 (15 November 2007); https://doi.org/10.1117/12.750320
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
LIDAR

Mirrors

Error analysis

Laser scanners

Scanners

3D scanning

Distortion

Back to Top