Paper
10 March 2009 Regularization of parallel MRI reconstruction using in vivo coil sensitivities
Qi Duan, Ricardo Otazo, Jian Xu, Daniel K. Sodickson
Author Affiliations +
Proceedings Volume 7258, Medical Imaging 2009: Physics of Medical Imaging; 72580Z (2009) https://doi.org/10.1117/12.812440
Event: SPIE Medical Imaging, 2009, Lake Buena Vista (Orlando Area), Florida, United States
Abstract
Parallel MRI can achieve increased spatiotemporal resolution in MRI by simultaneously sampling reduced k-space data with multiple receiver coils. One requirement that different parallel MRI techniques have in common is the need to determine spatial sensitivity information for the coil array. This is often done by smoothing the raw sensitivities obtained from low-resolution calibration images, for example via polynomial fitting. However, this sensitivity post-processing can be both time-consuming and error-prone. Another important factor in Parallel MRI is noise amplification in the reconstruction, which is due to non-unity transformations in the image reconstruction associated with spatially correlated coil sensitivity profiles. Generally, regularization approaches, such as Tikhonov and SVD-based methods, are applied to reduce SNR loss, at the price of introducing residual aliasing. In this work, we present a regularization approach using in vivo coil sensitivities in parallel MRI to overcome these potential errors into the reconstruction. The mathematical background of the proposed method is explained, and the technique is demonstrated with phantom images. The effectiveness of the proposed method is then illustrated clinically in a whole-heart 3D cardiac MR acquisition within a single breath-hold. The proposed method can not only overcome the sensitivity calibration problem, but also suppress a substantial portion of reconstruction-related noise without noticeable introduction of residual aliasing artifacts.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Qi Duan, Ricardo Otazo, Jian Xu, and Daniel K. Sodickson "Regularization of parallel MRI reconstruction using in vivo coil sensitivities", Proc. SPIE 7258, Medical Imaging 2009: Physics of Medical Imaging, 72580Z (10 March 2009); https://doi.org/10.1117/12.812440
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
In vivo imaging

Magnetic resonance imaging

Calibration

Computer programming

Signal to noise ratio

Brain

Interference (communication)

Back to Top