23 March 2010 New method to perform dosimetric quality control of treatment planning system using PENELOPE Monte Carlo and anatomical digital test objects
Yassine Benhdech, Stéphane Beaumont, Jean-Pierre Guédon, Tarraf Torfeh
Author Affiliations +
Abstract
In this paper, we deepen the R&D program named DTO-DC (Digital Object Test and Dosimetric Console), which goal is to develop an efficient, accurate and full method to achieve dosimetric quality control (QC) of radiotherapy treatment planning system (TPS). This method is mainly based on Digital Test Objects (DTOs) and on Monte Carlo (MC) simulation using the PENELOPE code [1]. These benchmark simulations can advantageously replace experimental measures typically used as reference for comparison with TPS calculated dose. Indeed, the MC simulations rather than dosimetric measurements allow contemplating QC without tying treatment devices and offer in many situations (i.p. heterogeneous medium, lack of scattering volume...) better accuracy compared to dose measurements with classical dosimetry equipment of a radiation therapy department. Furthermore using MC simulations and DTOs, i.e. a totally numerical QC tools, will also simplify QC implementation, and enable process automation; this allows radiotherapy centers to have a more complete and thorough QC. The program DTO-DC was established primarily on ELEKTA accelerator (photons mode) using non-anatomical DTOs [2]. Today our aim is to complete and apply this program on VARIAN accelerator (photons and electrons mode) using anatomical DTOs. First, we developed, modeled and created three anatomical DTOs in DICOM format: 'Head and Neck', Thorax and Pelvis. We parallelized the PENELOPE code using MPI libraries to accelerate their calculation, we have modeled in PENELOPE geometry Clinac head of Varian Clinac 2100CD (photons mode). Then, to implement this method, we calculated the dose distributions in Pelvis DTO using PENELOPE and ECLIPSE TPS. Finally we compared simulated and calculated dose distributions employing the relative difference proposed by Venselaar [3]. The results of this work demonstrate the feasibility of this method that provides a more accurate and easily achievable QC. Nonetheless, this method, implemented on ECLIPSE TPS version 8.6.15, has revealed large discrepancies (11%) between Monte Carlo simulations and the AAA algorithm calculations especially in equivalent air and equivalent bone areas. Our work will be completed by dose measurement (with film) in the presence of heterogeneous environment to validate MC simulations.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yassine Benhdech, Stéphane Beaumont, Jean-Pierre Guédon, and Tarraf Torfeh "New method to perform dosimetric quality control of treatment planning system using PENELOPE Monte Carlo and anatomical digital test objects", Proc. SPIE 7622, Medical Imaging 2010: Physics of Medical Imaging, 762250 (23 March 2010); https://doi.org/10.1117/12.844104
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Monte Carlo methods

Electrons

Head

Computed tomography

Photons

Optical simulations

Radiotherapy

Back to Top