We have developed a sandwiched immuno assay to detect sensitively Shiga-like toxins (SLTs) produced by Escherichia
coli O157:H7. The method involved the capture of toxins by specific immuno magnetic beads followed by tagging the
toxins with peroxidase-labeled anti E. coli O157:H7 antibody. Upon addition of proper substrate, peroxidase induced
luminescence was used to measure the presence of SLTs. We have previously demonstrated that co-incubation of shiga
toxin (SLT) producing E. coli O157:H7 with certain other bacteria can inhibit toxin production but does not affect the
growth of the E. coli. We show here that media in which the cells have grown been centrifuged from (conditioned
media) have similar effects on cell growth and SLT production. Adjusting the pH and adding nutrients to the
conditioned media did not have any effect on the reduction of SLT produced. Bacteria communicate with each other via
secreted sensing molecules. Several types of the molecules have been identified. However, the mechanisms of control
remain to be established. This pattern for bacteria growth and toxin production is also observed when quorum-sensing
molecules of homoserine lactone and indole are added to the media prior to inoculation.
An immuno sandwich method was evaluated for the detection of Salmonella in liquid eggs. Liquid eggs spiked with
different out-break strains of Salmonella were mixed with proper enrichment media and incubated at 37 C for 4 to 20 h.
After enrichment, immunomagnetic beads (IMB) coated with anti Salmonella antibodies were used to capture the
bacteria. Samarium (Sm) labeled anti Salmonella antibodies were then used to form sandwiched complexes with IMB
captured bacteria. Sandwiched Salmonella were then treated with Sm-chelator to allow the measurement of the released
Sm by time-resolved fluorescence (TRF). The processes ranging from IMB capture to Sm chelation were performed
using an automated KingFisher apparatus. With this approach, the presence of ~ 1 CFU of outbreak strains of
Salmonella Enteritidis per egg (~50 g of liquid eggs) could be detected after enrichment for 20 h at 37 C. For higher
levels of Salmonella Enteritidis contamination, e.g., 10 CFU per 50 g of liquid eggs, the enrichment time could be
reduced to 5 h at 37 C. The results demonstrated that a combination of IMB capture and TRF measurement could be a
rapid and sensitive method for Salmonella Enteritidis detection in liquid eggs.
A sandwiched immunoassay consisting of toxin capture by immunomagnetic beads (IMB) and toxin detection by horseradish peroxidase (HRP) linked chemiluminescence was used to follow the production of Shiga-like toxins (SLT) by E. coli O157:H7. The intensity of luminescence generated by the oxidation of luminol-liked compounds was used to represent the concentration of toxins produced. The time-course of SLT production by E. coli O157:H7 under different conditions was investigated. In pure culture, optimal generation of SLT showed a significant delay than the steady state of cell growth. In mixed cultures of SLT producing E. coli O157:H7 and non-SLT producing E. coli K-12 strain, the production of toxins was substantially decreased. However, the growth of E. coli O157:H7 was not affected by the presence of K-12 strain. This decrease in SLT production was also observed in radiation-sterile ground beef. In regular ground beef that might contain numerous other bacteria, the growth of E. coli O157:H7 in EC media was not significantly affected but the lowered production of SLT was observed. The results showed that mechanism of inducing SLT production was complex with both the growth time and growth environment could influence SLT production. The addition of homo-serine lactone to the growth media enhanced the production of SLT. Thus, possibly cell-cell communication may have a role in SLT production by E. coli O157:H7.
We developed an antibody-based fiber-optic biosensor to rapidly detect low levels of Escherichia coli O157:H7 and shiga-like toxins (SLTs) in ground beef samples. The principle of the sensor is a sandwich immunoassay using an antibody which is specific for E. coli O157:H7 or toxins. A polyclonal antibody was first immobilized on polystyrene fiber waveguides through a biotin-streptavidin reaction that served as the bacteria and toxin capture entity. Alexa Fluor 647 dye-labeled antibodies against E. coli O157:H7 or SLTS incubated with the waveguides were used to detect cells or toxin and generate a specific fluorescent signal, which was acquired by launching a 635 nm laser-light from an Analyte-2000. Fluorescent molecules within several hundred nanometers of the fiber were excited by an evanescent wave, and a portion of the emission light from fluorescent dye transmitted by the fiber and collected by a photodetector at wavelengths of 670 to 710 nm quantitatively. This immunosensor was specific for E. coli O157:H7 compared with multiple other foodborne bacteria. The approach was also able to detect ~0.5 μg/mL of pure SLTs and the the SLTs associated with 10 5 E. coli O157:H7 cells at stationary phase after olfoxacin induction.
A new fluorescent sandwich method for the detection of Escherichia coli O157:H7 was developed. Strepavidin coated magnetic beads and fluorescence beads reacted with biotinylated anti E. coli O157 antibodies to form the immuno magnetic beads (IMB) and immuno fluorescence beads (IFB), respectively. The E. coli bacteria captured by IMB were further labeled with IFB to form
IMBM-(E. coliO157:H7)N-IFBO sandwich complexes where the subscripts M, N and O were integral numbers. Using broth cultured E. coli O157:H7, the sandwich method was able to detect the bacteria at the level of ~ 103to 104 CFU/mL. Known quantity of freshly cultured E. coli O157:H7 cells were added to ground beef obtained from local markets. The bacteria in inoculated beef patties were enriched in EC broth containing novobiocin. After enriched for 4 h at 40 °C, the developed IMB-IFB method was applied to detect the presence of E. coli O157:H7. The results demonstrated that the developed method could detect the presence of 1 CFU of E. coli O157:H7 per gram of ground beef.
Outbreaks of E. coli O157:H7 by the consumption of contaminated cantaloupes fruits have been documented. Pathogens harbored in the networked but porous veins in khaki colored skin are difficult to remove. Thus, sensitive and efficient methods are needed to detect the presence of E. coli O157:H7 in cantaloupes. In this work, known quantities of the E. coli were inoculated on cantaloupe skins or flesh at room temperature for 1 h. The contaminated samples were incubated in growth media at 37°C for 3.3h. The bacteria captured by magnetic beads coated with anti E. coli O157 antibodies were further sandwiched by second anti E.coli O157 antibodies containing peroxidase for chemiluminescent measurements of captured bacteria. Alternatively, the captured bacteria were treated with electron-shuttering reagent to detect the cellular level of NAD(P)H via bioluminescence. The detected enzyme activity (peroxidase) and the NAD(P)H were used to measure the presence of the pathogen. The results indicated both the chemiluminescence and the fluorescence methods, in 96 well microplate format, could be applied to detect the E. coli contamination of cantaloupes.
Commercially available alfalfa seeds were inoculated with low levels (~ 4 CFU/g) of pathogenic bacteria. The
inoculated seeds were then allowed to sprout in sterile tap water at 22°C. After 48 hours, the irrigation water and
sprouts were separately transferred to bovine heart infusion (BHI) media. The microbes in the BHI samples were
allowed to grow for 4 hours at 37°C and 160 rpm. Specific immunomagnetic beads (IMB) were then applied to capture
the E.coli O157 and/or Salmonella in the growth media. Separation and concentration of IMB-captured pathogens were
achieved using magnetic separators. The captured E. coli O157:H7 and Salmonella spp were further tagged with
europium (Eu) labeled anti-E. coli O157 antibodies and samarium (Sm) labeled anti-Salmonella antibodies, respectively.
After washing, the lanthanide labels were extracted out from the complexes by specific chelators to form strongly
fluorescent chelates. The specific time-resolved fluorescence (TRF) associated with Eu or Sm was measured to estimate
the extent of capture of the E. coli O157 and Salmonella, respectively. The results indicated that the approach could
detect E. coli O157 and Salmonella enterica from the seeds inoculated with ~ 4 CFU/g of the pathogens. Non-targeted
bacteria, e.g., Aeromonas and Citrobacter exhibited essentially no cross reactivity. Since the pathogen detection from
the sprouts was achieved within 6 hours, the developed methodology could be use as a rapid, sensitive and specific
screening process for E. coli O157 and Salmonella enterica in this popular salad food.
An improved process using magnetic capture of antibody-conjugated bacteria for light addressable potentiometric sensor detection by the Threshold instrument was developed. Cells of Escherichia coli 0157:H7 were captured by the biotinylated anti-E. coli 0157 antibodies conjugated to streptavidin coated magnetic beads. Magnetically concentrated bacteria were further labeled with by fluorescein-conjugated anti-E. coli 0157 antibodies that were bound to urease-conjugated antifluorescein antibody. The whole bacteria-containing complex was then immobilized on 0.45? biotinylated nitro-cellulose membranes via streptavidin-biotin interactions. The rates of pH change associated with the production of NH3 by conjugated urease were measured by a LAPS technique incorporated in the Threshold instrument. This approach allowed us to detect io CFU of cultured E. coli 0157:H7 in tris-buffered saline (TBS). The same approach was applied to detect the E. coli in beef hamburger spiked with the bacteria. After a 5 to 6-hour enrichment, as low as 1 CFU/g of E. coli 0157:H7 in the hamburger could be detected. In addition, the immobilized bacterial complexes on the nitro-cellulose membranes exhibited a stability longer than 48 h at 4 and 22 °C in TBS allowing the possibility of conveniently shipping collected samples rather than raw beef to testing laboratories.
Live cells of E. coliO157:H7 were captured by goat anti-E. coliO157 serum coated on the surface of polystyrene based immunomagnetic beads (IMB). The captured bacteria were labeled by 4',6-diamidino-2-phenylindole (DAPI), a nucleic acid stain, for observation by epifluorescent microscopy. The beads with captured bacteria were then concentrated by magnetic separators. The efficiency of this magnetic concentration step was less than that of using high speed centrifugation. The antibody-captured and IMB-immobilized bacteria were then applied on HF-treated, bovine serum albumin (BSA)-coated microscope slides mounted on an automated stage, and magnetically aligned before fluorescence distribution was measured by a cooled CCD attached to an inverted microscope. Since the beads were concentrated and linearly aligned along the edge of the magnetic field, image capture along the edge for a few field widths was sufficient to account for most of captured bacteria. We applied this approach to determine the bacterial counts in spiked beef hamburger patties. The results showed that after a 6-hour enrichment, sufficient number of the bacteria could be detected from the samples spiked with 1 CFU of E. coliO157:H7 per gram of the hamburger.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please