We present a novel akinetic optical ultrasound sensor, consisting of a rigid, fiber-coupled Fabry-P´erot interferometer (FPI) with a central opening. The sensing principle relies exclusively on the detection of pressure-induced changes of the refractive index in the liquid located between the cavity mirrors. This enables resonance-free, inherently linear signal detection over a large bandwidth. We demonstrate that the sensor allows to realize exceedingly low noise equivalent pressure (NEP) values of 2 Pa over a 20 MHz measurement bandwidth, while maintaining a large full field of view of 2,7mm × 1,3mm as well as a flat frequency response. Imaging tests on phantoms and biological tissue show the suitability of the XARION-sensor for optical resolution photoacoustic microscopy (OR-PAM) applications. Transparent in axial direction, the sensor facilitates the implementation of highly sensitive fast-scanning reflection-mode OR-PAM setups, as well as easy integration with other imaging modalities such as confocal microscopy or OCT.
Measurement and imaging of depolarization by polarization-sensitive optical coherence tomography (PS-OCT) requires averaging of Stokes vector elements within two- or three-dimensional (3-D) evaluation windows to obtain the degree of polarization uniformity (DOPU). By use of a PS-OCT system with an integrated retinal tracker, we analyze optimum conditions for depolarization imaging, data processing, and segmentation of depolarizing tissue in the human retina. The trade-offs between figures of merit like DOPU imaging sensitivity, efficiency, and susceptibility are evaluated in terms of 3-D resolution. The results are used for a new, detailed interpretation of PS-OCT high-resolution images of the human retinal pigment epithelium and Bruch’s membrane.
We developed a three-beam Doppler optical coherence tomography (OCT) system that enables measurement of the velocity vector of moving particles in three-dimensions (3-D). The spatial orientation as well as the magnitude of motion can be determined without prior knowledge of the geometry of motion. The system combines three spectral-domain OCT interferometers whose sample beams are focused at the sample by a common focusing lens at three different angles. This provides three spatially independent velocity components simultaneously from which the velocity vector can be reconstructed. We demonstrate the system in a simple test object (rotating disc), a flow phantom, and for blood flow measurements in the retina of a healthy human subject. Measurements of blood flow at a venous bifurcation achieve a good agreement between in- and outflow and demonstrate the reliability of the method.
We present a novel, high-speed, polarization-sensitive, optical coherence tomography set-up for retinal imaging operating at a central wavelength of 1060 nm which was tested for in vivo imaging in healthy human volunteers. We use the system in combination with a Fourier domain mode locked laser with active spectral shaping which enables the use of forward and backward sweep in order to double the imaging speed without a buffering stage. With this approach and with a custom designed data acquisition system, we show polarization-sensitive imaging with an A-scan rate of 350 kHz. The acquired three-dimensional data sets of healthy human volunteers show different polarization characteristics in the eye, such as depolarization in the retinal pigment epithelium and birefringence in retinal nerve fiber layer and sclera. The increased speed allows imaging of large volumes with reduced motion artifacts. Moreover, averaging several two-dimensional frames allows the generation of high-definition B-scans without the use of an eye-tracking system. The increased penetration depth of the system, which is caused by the longer probing beam wavelength, is beneficial for imaging choroidal and scleral structures and allows automated segmentation of these layers based on their polarization characteristics.
Optical coherence tomography (OCT) in the 1060nm range is interesting for in vivo imaging of the human
posterior eye segment (retina, choroid, sclera), as it permits a long penetration depth. Complementary to
structural images, polarization-sensitive OCT (PS-OCT) images visualize birefringent, polarization-maintaining
or depolarizing areas within the sample. This information can be used to distinguish retinal layers and structures
with different polarization properties. High imaging speed is crucial for imaging ocular structures in vivo in order
to minimize motion artifacts while acquiring sufficiently large datasets. Here, we demonstrate PS-OCT imaging
at 350 kHz A-scan rate using a two-channel PS-OCT system in conjunction with a Fourier domain mode-locked
laser. The light source spectrum spans up to 100nm around the water absorption minimum at 1060 nm. By
modulating the laser pump current, we can optimize the spectrum and achieve a depth resolution of 9 μm in air
(6.5 μm in tissue). We acquired retinal images in vivo with high resolution and deep penetration into choroid and
sclera, and features like the depolarizing RPE or an increasing phase retardation at the chorio-scleral interface
are clearly visualized.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.