Caries of the interdental space are usually difficult to detect with conventional bitewing radiography. We have developed an interdental probe for polarization-sensitive optical coherence tomography (PSOCT) that can distinguish between healthy and carious tooth structures. The development is based on a fiber optic probe with a compact motor design that allows volumetric imaging. In a clinical study, demineralization was detected using proximal PSOCT scans of premolars and molars, and compared with blind diagnoses from four dentists. The results show that PSOCT can detect both, early demineralization and advanced proximal caries, some of which could not be diagnosed with bitewing radiography.
Optical coherence tomography (OCT) is a non-invasive, radiation-free optical technique for caries diagnosis. The presented study dealt with the correlation of conventional caries detection methods and using polarisation-sensitive OCT (PS-OCT). Human extracted carious teeth were assessed by dentists with visual and radiographic examination and PS-OCT images were gained. Proximal lesions could be detected early in the intensity-based OCT cross-sectional images. The degree of polarization can clearly delineate proximal caries from surrounding healthy tooth structure. The obtained results pave the way to reduce invasive filling therapy through early possibilities of intervention.
The detection of incipient carious lesions is crucial for the preservation of dental hard tissue with preventive therapies. Optical coherence tomography (OCT) based imaging has been proofed to be a valuable methodology for the depth-resolved detection of alterations at dental hard tissue. Due to changes of birefringent properties at carious lesions, the measurement of polarization properties with polarization-sensitive OCT (PS-OCT) provides an additional contrast that could enhance the detection of incipient carious lesions. The aim of the present study was to monitor changes of polarization properties during the initial demineralization process by means of PS-OCT. Therefore, 18 bovine enamel palates were demineralized up to 7 weeks in an artificial demineralization model using lactate acid and buffer solution to mimic natural caries progression. The palates were stored at pH 5.5 and 35°C with constant fluid movement. In order to detect changes of depolarization at different stages of demineralization, the degree of polarization uniformity (DOPU) was calculated from PS-OCT measurements, performed under wet and dry conditions. In addition, polarization microscopy and micro-computed tomography of thin sections were analyzed to assess lesion depth and mineral loss. Our main finding is that consecutive stages of demineralization are correlated to an increasing DOPU contrast between sound enamel and the lesion area, where the lesion area is connected to decreasing DOPU values. Our results show that PS-OCT based imaging of birefringence changes is sensitive to very early stages of the demineralization process and adds a valuable contrast for the detection and monitoring of incipient enamel lesions.
The common way to diagnose hard and soft tissue irregularities in the oral cavity is initially the visual inspection by an experienced dentist followed by further medical examinations, such as radiological imaging and/or histopathological investigation. For the diagnosis of oral hard and soft tissues, the detection of early transformations is mostly hampered by poor visual access, low specificity of the diagnosis techniques, and/or limited feasibility of frequent screenings. Therefore, optical noninvasive diagnosis of oral tissue is promising to improve the accuracy of oral screening. Considering this demand, a rigid handheld endoscopic scanner was developed for optical coherence tomography (OCT). The novelty is the usage of a commercially near-infrared endoscope with fitting optics in combination with an established spectral-domain OCT system of our workgroup. By reaching a high spatial resolution, in vivo images of anterior and especially posterior dental and mucosal tissues were obtained from the oral cavity of two volunteers. The convincing image quality of the endoscopic OCT device is particularly obvious for the imaging of different regions of the human soft palate with highly scattering fibrous layer and capillary network within the lamina propria.
As dental caries is one of the most common diseases, the early and noninvasive detection of carious lesions plays an important role in public health care. Optical coherence tomography (OCT) with its ability of depth-resolved, high-resolution, noninvasive, fast imaging has been previously recognized as a promising tool in dentistry. Additionally, polarization sensitive imaging provides quantitative measures on the birefringent tissue properties and can be utilized for imaging dental tissue, especially enamel and dentin. By imaging three exemplary tooth samples ex vivo with proximal white spot, brown spot, and cavity, we show that the combination of polarization sensitive OCT and the degree of polarization uniformity (DOPU) algorithm is a promising approach for the detection of proximal carious lesions due to the depolarization contrast of demineralized tissue. Furthermore, we investigate different sizes of the DOPU evaluation kernel on the resulting contrast and conclude a suitable value for this application. We propose that DOPU provides an easy to interpret image representation and appropriate contrast for possible future screening applications in early caries diagnostics.
Since optical coherence tomography (OCT) provides three-dimensional high-resolution images of biological tissue, the benefit of polarization contrast in the field of dentistry is highlighted in this study. Polarization-sensitive OCT (PS OCT) with phase-sensitive recording is used for imaging dental and mucosal tissues in the human oral cavity in vivo. An enhanced polarization contrast of oral structures is reached by analyzing the signals of the co- and crosspolarized channels of the swept source PS OCT system quantitatively with respect to reflectivity, retardation, optic axis orientation, and depolarization. The calculation of these polarization parameters enables a high tissue-specific contrast imaging for the detailed physical interpretation of human oral hard and soft tissues. For the proof-of-principle, imaging of composite restorations and mineralization defects at premolars as well as gingival, lingual, and labial oral mucosa was performed in vivo within the anterior oral cavity. The achieved contrast-enhanced results of the investigated human oral tissues by means of polarization-sensitive imaging are evaluated by the comparison with conventional intensity-based OCT.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.