This will count as one of your downloads.
You will have access to both the presentation and article (if available).
COSMO is a cryogenic Martin-Puplett Fourier Transform Spectrometer that aims at measuring the isotropic y-type spectral distortion of the Cosmic Microwave Background from Antarctica, by performing differential measurements between the sky and an internal, cryogenic reference blackbody. To reduce the atmospheric contribution, a spinning wedge mirror performs fast sky-dips at varying elevations while fast, low-noise Kinetic Inductance detectors scan the interferogram.
Two arrays of antennas couple the radiation to the detectors. Each array consists of nine smooth-walled multi-mode feed-horns, operating in the 120−180 GHz and 210−300 GHz range, respectively. The multi-mode propagation helps increase the instrumental sensitivity without employing large focal planes with hundreds of detectors. The two arrays have a step-linear and a linear profile, respectively, and are obtained by superimposing aluminum plates made with CNC milling. The simulated multi-mode beam pattern has a ~ 20° − 26° FWHM for the low-frequency array and ~16° FWHM for the high-frequency one. The side lobes are below −15 dB.
To characterize the antenna response, we measured the beam pattern of the fundamental mode using a Vector Network Analyzer, in far-field conditions inside an anechoic chamber at room temperature. We completed the measurements of the low-frequency array and found a good agreement with the simulations. We also identified a few non-idealities that we attribute to the measuring setup and will further investigate. A comprehensive multi-mode measurement will be feasible at cryogenic temperature once the full receiver is integrated.
The voltage-biased TES are read out with Time Domain Multiplexing and an unprecedented multiplexing (MUX) factor equal to 128. This MUX factor is reached with two-stage multiplexing: a traditional one exploiting Superconducting QUantum Interference Devices (SQUIDs) at 1K and a novel SiGe Application-Specific Integrated Circuit (ASIC) at 60 K. The former provides a MUX factor of 32, while the latter provides a further 4. Each TES array is composed of 256 detectors and read out with four modules of 32 SQUIDs and two ASICs. A custom software synchronizes and manages the readout and detector operation, while the TES are sampled at 780 Hz (100kHz/128 MUX rate).
In this work we present the experimental characterization of the QUBIC TES arrays and their multiplexing readout chain, including time constant, critical temperature, and noise properties.
The technical demonstrator is a scaled-down version of Module 1 in terms of the number of detectors, input horns and pulse tubes and a reduction in the diameter of the combiner mirrors and filters, but is otherwise similar. The demonstrator will be upgraded to the full module in 2019. In this paper we give an overview of the QUBIC project and instrument.
The full QUBIC instrument is described elsewhere1,2,3,4; in this paper we will concentrate in particular on simulations of the optical combiner (an off-axis Gregorian imager) and the feedhorn array. We model the optical performance of both the QUBIC full module and a scaled-down technological demonstrator which will be used to validate the full instrument design. Optical modelling is carried out using full vector physical optics with a combination of commercial and in-house software. In the high-frequency channel we must be careful to consider the higher-order modes that can be transmitted by the horn array. The instrument window function is used as a measure of performance and we investigate the effect of, for example, alignment and manufacturing tolerances, truncation by optical components and off-axis aberrations. We also report on laboratory tests carried on the QUBIC technological demonstrator in advance of deployment to the observing site in Argentina.
The beam from each feedhorn is passed through an optical combiner, with an off-axis compensated Gregorian design, to allow the generation of the synthetic image. The optical-combiner will operate in two frequency bands (150 and 220 GHz with 25% and 18.2 % bandwidth respectively) while cryogenically cooled TES bolometers provide the sensitivity required at the image plane.
The QUBIC Technical Demonstrator (TD), a proof of technology instrument that contains 64 input feed-horns, is currently being built and will be installed in the Alto Chorrillos region of Argentina. The plan is then for the full QUBIC instrument (400 feed-horns) to be deployed in Argentina and obtain cosmologically significant results.
In this paper we will examine the output of the manufactered feed-horns in comparison to the nominal design. We will show the results of optical modelling that has been performed in anticipation of alignment and calibration of the TD in Paris, in particular testing the validity of real laboratory environments. We show the output of large calibrator sources (50 ° full width haf max Gaussian beams) and the importance of accurate mirror definitions when modelling large beams. Finally we describe the tolerance on errors of the position and orientation of mirrors in the optical combiner.
View contact details
No SPIE Account? Create one