We present the first full-array optical characterizations of the 280 GHz aluminum-based superconducting microwave kinetic inductance detector (MKID) arrays developed at NIST, CO, USA for the CCAT Collaboration for observing galactic ecology, Sunyaev-Zel'dovich effect, galaxy evolution, and line intensity mapping. The main advantage of aluminum MKIDs is their lower 1/f noise compared to the alternative choice of titanium-nitride (TiN) MKIDs, which would reduce systematic drifts when mapping the sky. We will present the spectral response, polarization characteristics, detector efficiency, and noise equivalent power (NEP) under the relevant conditions for these detectors. Two aluminum and one TiN MKID arrays will form the detector arrays in the 280 GHz instrument module of the Prime-Cam. First light observations are expected in 2025.
Prime-Cam, a first-generation science instrument for the Atacama-based Fred Young Submillimeter Telescope, is being built by the CCAT Collaboration to observe at millimeter and submillimeter wavelengths using kinetic inductance detectors (KIDs). Prime-Cam’s 280 GHz instrument module will deploy with two aluminum-based KID arrays and one titanium nitride-based KID array, totaling ∼10,000 detectors at the focal plane, all of which have been fabricated and are currently undergoing testing. One complication of fielding large arrays of KIDs under dynamic loading conditions is tuning the detector tone powers to maximize signal-to-noise while avoiding bifurcation due to the nonlinear kinetic inductance. For aluminum-based KIDs, this is further complicated by additional nonlinear effects which couple tone power to resonator quality factors and resonant frequencies. While both nonequilibrium quasiparticle dynamics and two-level system fluctuations have been shown to give rise to qualitatively similar distortions, modeling these effects alongside nonlinear kinetic inductance is inefficient when fitting thousands of resonators on-sky with existing models. For this reason, it is necessary to have a detailed understanding of the nonlinear effects across relevant detector loading conditions, including how they impact on on-sky noise and how to diagnose the detector’s relative performance. We present a study of the competing nonlinearities seen in Prime-Cam’s 280 GHz aluminum KIDs, with a particular emphasis on the resulting distortions to the resonator line shape and how these impact detector parameter estimation.
The Epoch of Reionization Spectrometer (EoR-Spec) is an upcoming Line Intensity Mapping (LIM) instrument designed to study the evolution of the early universe (z = 3.5 to 8) by probing the redshifted [CII] 158 μm fine-structure line from aggregates of galaxies. The [CII] emission is an excellent tracer of star formation since it is the dominant cooling line from neutral gas heated by OB star light and thus can be used to probe the reionization of the early Universe due to star formation. EoR-Spec will be deployed on Prime-Cam, a modular direct-detection receiver for the 6-meter Fred Young Submillimeter Telescope (FYST), currently under construction by CPI Vertex Antennentechnik GmbH and to be installed near the summit of Cerro Chajnantor in the Atacama Desert. This instrument features an image plane populated with more than 6500 Microwave Kinetic Inductance Detectors (MKIDs) that are illuminated by a 4-lens optical design with a cryogenic, scanning Fabry-Perot Interferometer (FPI) at the pupil of the optical system. The FPI is designed to provide a spectral resolving power of R ∼ 100 over the full spectral range of 210–420 GHz. EoR-Spec will tomographically survey the E-COSMOS and E-CDFS fields with a depth of about 4000 hours over a 5 year period. Here we give an update on EoR-Spec’s final mechanical/optical design and the current status of fabrication, characterization and testing towards first light in 2026.
The Fred Young Submillimeter Telescope (FYST), on Cerro Chajnantor in the Atacama desert of Chile, will conduct wide-field and small deep-field surveys of the sky with more than 100,000 detectors on the Prime-Cam instrument. Kinetic inductance detectors (KIDs) were chosen as the primary sensor technology for their high density focal plane packing. Additionally, they benefit from low cost, ease of fabrication, and simplified cryogenic readout, which are all beneficial for successful deployment at scale. The cryogenic multiplexing complexity is pulled out of the cryostat and is instead pushed into the digital signal processing of the room temperature electronics. Using the Xilinx Radio Frequency System on a Chip (RFSoC), a highly multiplexed KID readout was developed for the first light Prime-Cam and commissioning Mod-Cam instruments. We report on the performance of the RFSoC-based readout with multiple detector arrays in various cryogenic setups. Specifically we demonstrate detector noise limited performance of the RFSoC-based readout under the expected optical loading conditions.
Prime-Cam is a first-generation science instrument for the CCAT Observatory’s six-meter aperture Fred Young Submillimeter Telescope (FYST). FYST’s crossed-Dragone design provides high optical throughput to take advantage of its unique site at 5600 m on Cerro Chajnantor in Chile’s Atacama Desert to reach mapping speeds over ten times greater than current and near-term submillimeter experiments. Housing up to seven independent instrument modules in its 1.8-meter diameter cryostat, Prime-Cam will combine broadband polarization-sensitive modules and spectrometer modules designed for observations in several frequency windows between 210 GHz and 850 GHz to study a wide range of astrophysical questions from Big Bang cosmology to the formation of stars and galaxies in the Epoch of Reionization and beyond. In order to cover this range of frequencies and observation modes, each of the modules contains a set of cold reimaging optics that is optimized for the science goals of that module. These optical setups include several filters, three or four anti-reflection-coated silicon lenses, and a Lyot stop to control the field of view and illumination of the primary mirror, satisfy a series of mechanical constraints, and maximize optical performance within each passband. We summarize the design considerations and trade-offs for the optics in these modules and provide a status update on the fabrication of the Prime-Cam receiver and the design of its 1 K and 100 mK thermal BUSs.
Current and future experiments observing the cosmic microwave background require a detailed understanding of optical performance at cryogenic temperatures. Pre-deployment analysis of optics can be performed in custom-engineered cryogenic test beds, such as Mod-Cam, a first light camera for the CCAT project. This work presents studies of the mechanical and thermal performance of CryoSim, a model of a generic cylindrical 4-K cryostat cooled with a commercial pulse tube cryocooler that can be used to characterise optical components and full reimaging optical systems. CryoSim is extensively parametrised, allowing the joint analysis and optimisation of mechanical and thermal performance via finite element methods. Results from this model are validated against measured cooldown data of the Mod-Cam cryostat. Due to the extensive parametrisation of the model, significant modifications of the cryostat geometry may be implemented to be representative of any system the scientific community may desire, and validation of thermal and mechanical performance can be carried out rapidly.
KEYWORDS: Sensors, Resonators, Detector arrays, Data acquisition, Signal attenuation, Equipment, Quantum reading, Calibration, Signal processing, Signal detection
We outline the development of the readout software for the Prime-Cam and Mod-Cam instruments on the CCAT Fred Young Submillimeter Telescope (FYST), primecam readout. The instruments feature Lumped-element Kinetic Inductance Detector (LEKID) arrays driven by Xilinx ZCU111 RFSoC boards. In the current configuration, each board can drive up to 4000 KIDs, and Prime-Cam is implementing approximately 25 boards. The software runs on a centralized control computer connected to the boards via dedicated ethernet and facilitates such tasks as frequency-multiplexed tone comb driving, comb calibration and optimization, and detector timestream establishment. The control computer utilizes dynamically generated control channels for each board, allowing for simultaneous parallel control overall, while uniquely tracking diagnostics for each. This work demonstrates a scalable RFSoC readout architecture where computational demands increase linearly with the number of detectors, enabling control of tens-of-thousands of KIDs with modest hardware, and opening the door to the next generation of KID arrays housing millions of detectors.
Prime-Cam is a first-generation instrument for the Cerro Chajnantor Atacama Telescope-prime (CCAT-prime) Facility. The 850 GHz module for Prime-Cam will probe the highest frequency of all the instrument modules. We describe the parameter space of the 850 GHz optical system between the Fλ spacing, beam size, pixel sensitivity, and detector count. We present the optimization of an optical design for the 850 GHz instrument module for CCAT-prime. We further describe the development of the cryogenic RF chain design to accommodate 30 readout lines to read 41,400 kinetic inductance detectors (KIDs) within the cryogenic testbed.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.